Dodging data downtime


Alex Blake, Business Development Director at ABM Critical Solutions, discusses the importance of cleaning and maintenance of flooring in data centres.


Maintaining a data centre requires constant monitoring to ensure all equipment is working efficiently and technical cleans are carried out regularly to prevent critical equipment failure that can come about through air particle contamination.


When it comes to flooring in data centres, there are three major areas of consideration for facilities management: adapting to flooring design evolution, effective execution of raised access flooring replacement work, and the importance of regular and specialist technical cleaning.


Historically the cavity in raised access flooring (RAF) has been used to house cables that provide power and connectivity, as well as acting as a floor void plenum chamber to allow delivery of conditioned air to the underside of the server racks. However poor cable management, which can restrict the correct air path for cooling systems, has led to new flooring designs which sees cables now stored above the critical equipment instead.


This leaves more space below the floor for cooling infrastructure which is vital to the day-to-day running of the data centre. Whether installation or maintenance is the focus, it’s important to understand the construction of the equipment in the room and whether it features a design which allows for more or less cooling space in order to adapt maintenance or cleaning plans accordingly. This aspect is vital as overheating in a critical space can result in a circuit shortage. Downtime in a data centre can mean a huge loss of earnings for business so it is to be avoided at all costs.


RAF replacements are usually carried out when a critical space is expanding, an area has been damaged, or when there is a threat of Zinc Whisker contamination. Correct RAF replacement requires installation of zip walls into the main data hall to stop any cross contamination around the ‘clean zones’ of the remaining data hall. Plenum air flow baffles should also be installed inside the floor void to stop contamination entering the ‘clean’ areas.


64 | FLOORCARE & MAINTENANCE


It is vital that qualified technicians such as ABM Critical Solutions carry out these projects to ensure all correct procedures are in place to prevent system failures. It’s also worth noting that other elements required for an optimum data centre environment include the ability to handle a large number of cables, and the ability to adapt for future technological and cooling advancements.


Finally, regular technical cleans to the subfloor are essential and should be completed using specialised equipment and materials, including triple-filtration high-efficiency particulate air (HEPA) or S-Class vacuums. Commercial vacuums without the HEPA filtration filter systems allow particles back into the room. Underfloor contaminates left within the floor void increase the risk of unexplained server outages which can be caused by particulate matter with a conductive element being caught within the flow of conditioned air, and finding its way onto printed circuit boards.


It is essential that technicians are trained to identify Zinc Whiskers – something that ABM Critical Solutions offers as mandatory during a technical clean. Scanning Electron Microscopy (SEM) testing is also performed on the suspected areas: the analysis is collected on a sticky tape stud which is examined using a scanning electron microscope and energy-dispersive X-ray analysis (EXD).


Low speed and high speed electric floor rotary machines should be used to cleanse the raised floor surface within the data hall; the buffers allow for interchangeable cleaning pads to be used. These ensure the contaminated floors are thoroughly cleaned and ready for use.


Human error and infrastructure failure caused by insufficient maintenance are the main reasons for critical downtime and outages, but they can be avoided if the above steps are followed correctly.


www.abm.co.uk www.abm.co.uk/critical-solutions twitter.com/TomoCleaning


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76