COATING TECHNOLOGY


SECTION TITLE


DLC coatings for components, the advanced ta-C coating Balinit Milubia has the best tribological properties for reducing COF in water environments. With a typical hardness of 40 to 60 GPa, ta-C coatings are an excellent choice for components that are exposed to extreme operating forces over the long-term, such as shafts and seals, where friction can cause components to overheat or fail. Te ta-C coating is typically applied in a thickness of only 0.5-2μm using a method of physical vapour deposition (PVD) by arc evaporation. Tis produces ta-C, which has substantially higher abrasive wear resistance than a-C:H alternatives. Because the coating can be applied at a temperature below 150°F (65°C), unique even within the DLC family, it can be applied to thermally sensitive substrates such as polymers and elastomers that before now have been difficult to coat. “Among all DLC coatings, Balinit


Milubia provides the lowest friction coefficient possible compared to other materials and uncoated metals, ceramics, polymers, and elastomers in water environments. Even under dry running conditions, the ta-C coating can deliver a very low COF that approaches zero,” says Jarry.


RESOLVING COATING CHALLENGES Te unique properties of ta-C coatings allow manufacturers to resolve some of the challenging issues for components made of ceramics, polymers and elastomers including hydraulic pump parts, mechanical seals, and high-pressure valve components. Pump, valve and tap components are often made of ceramics such as alumina (Al2O3) and silicon carbide (SiC) due to relatively low cost and superior corrosion resistance over metals in wet environments. Since ceramics are already very hard, wear is not typically a major concern. Although the ta-C coating can increase the hardness of an alumina component from 2,000 Vickers to approximately 4,000, that is not the primary objective. Ceramics can still be affected by high friction, however, which wears down parts quickly and can increase internal operating temperatures to levels that can damage nearby components. In these cases, a ta-C coating can dramatically reduce the COF and associated thermal rise. One potential application is ceramic pump shafts and bearings, which are expected to perform reliably over the long term in corrosive conditions. When coated


Oerlikon’s coating reduces friction of sliding ceramic, metallic, and polymer components.


with ta-C, these parts approach a COF of 0.1, compared to nearly 0.5 uncoated. Perhaps even more importantly, the COF is nearly the same under dry running conditions. Tis protects pump components such as ceramic seals or O-rings from friction, thermal rise, and damage if an operator runs the equipment “dry.” Mechanical seals for centrifugal water pumps, for example, are often made of SiC. Typically, dry running mechanical seals or O-rings can “burn” them, causing failure and requiring premature replacement. Lowering the COF reduces the heat generation and allows longer dry running times without failures. “In this type of situation, the coating essentially allows the pump to survive despite some misuse,” explains Jarry. Less friction lowers the energy consumption as well, he adds.


Unlike ceramics, polymers are relatively soft and quickly wear or are damaged in high contact, high friction applications. When the ta-C DLC coating is applied over a polymer substrate, it can provide a coating hardness of up to 50 GPa to increase component durability and lifespan. However, polymers are traditionally difficult to coat with DLC coatings. “Polymer substrates have low thermal stability so can melt or deform at the higher temperatures that most PVD coatings require,” says Jarry. “Fortunately, the ta-C coating can be applied at a temperature below 65°C, which is low enough to avoid thermal deformation of most polymers.”


Iindustrial thin film coatings can reduce friction to dramatically improve the life and performance of critical components


EXPLORING NEW OPPORTUNITIES Jarry adds that manufacturers are increasingly directing intriguing applications during the testing phase. “During testing, a customer often develops an awareness of what the coating is capable of – we integrate that into next generation designs. Tis can involve modifying part shape, base materials, and other design elements.” Te bottom line for manufacturers of components often in contact with other parts and/or submersed in water is that innovative coatings are changing what is possible. When a lower COF is required for mated or sliding parts, specialised PVD coatings can be applied in thicknesses of only a few micrometres at low temperature to further harden the surface and dramatically lower the coefficient of friction. Given the advances in hydrogen- free DLC coatings, ta-C is showing great promise in delivering the best tribological properties in boundary lubrication and water environments.


www.engineerlive.com 29


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52