Air Monitoring 23
process monitor. The process monitor is used to provide real time feedback to control the carbon injection rate. A special note for clarity regarding the Ohio Lumex 915J; although the 915J mercury process monitor is a continuous mercury monitor, Ohio Lumex does not market this instrument for compliance in the U.S. because it is specifically designed for process control. The data below shows 915J process monitor results represented in blue versus the sorbent trap data represented in red for an almost 3-month period of time. The 915J is very accurate and tracks very well with the sorbent trap data. This plant has two coal-fired units, both 850 MW, that have a combined 97% rate of data availability using sorbent traps for mercury compliance reporting. The use of the 915J process monitor to control carbon injection rate has saved the plant a considerable amount in carbon costs thus keeping the plant very profitable. This source also has higher than normal SO2
new mercury regulations, almost every plant in the U.S. that initially chose to use sorbent traps continues to use sorbent trap monitoring for compliance and many of the plants that chose to use mercury CEMS initially now use sorbent traps for compliance because of reliability issues related to the mercury CEMS. The best
takeaway from the U.S. plants’ experiences is to start conducting sorbent trap testing early before the regulations go into effect and discover the particular characteristics of your source so you can decide which method of mercury monitoring is best for your plant.
levels, typically between 210 ppm to 230 ppm, which can add to sampling issues with traditional CEMMs. However, the sorbent trap configuration for this source has an acid gas scrubber section added to prevent analysis breakthrough issues.
Case Study 2 Data
The second data set is from a cement plant burning bituminous coal and tires that uses sorbent traps for mercury compliance monitoring. This plant has had to do carbon injection to reduce mercury emissions as well as dust shuttling to get below the NESHAP Hg emission limit of 55 pounds per million ton of clinker, averaged over 30 days. They have also installed a Compliance CEMM to act as a process monitor giving real-time feedback to control the injection rate of activated carbon for mercury control. Some of the challenges at a cement plant include large changes in temperature and mercury levels. Kilns with an in-line raw mill can vary in temperature from 330°F to 450°F and mercury levels can go from 5-7 ug/scm up to 50-100 ug/scm for short periods of time. This is where sorbent traps can have a distinct advantage over mercury CEMS because sorbent traps can handle large increases in mercury. The surges will only increase the average mercury concentration for a given period, several days for example. Unlike with mercury CEMS where in these instances, one would have to deal with mercury calibration gases covering the span of the mercury concentrations observed during raw mill off events. Looking at the sorbent trap data shown in blue and the mercury CEMS data shown in green below, you can see that in the beginning (shortly after this mercury CEMS was serviced) both the sorbent traps and CEMM tracked close to one another. But as time went on, the deviation grew larger with the mercury CEMS showing about a 28% lower mercury concentration. On occasion, we are asked which data is most accurate and the answer is very simple when comparing sorbent traps to mercury CEMS. If the sorbent traps have passed all the QA/QC requirements for both sampling and analysis and they are utilizing the EPA reference method (Method 30B), the answer is that sorbent traps are the most accurate data represented. Also of note, most cement plants in the U.S. using sorbent traps for compliance have an average data availability rate of 95%.
Summary
Over the last 13 years of working with 200+ power plants, incinerators, and over 40 cement plants we have learned that each source is unique and faces its own challenges. This knowledge has led us to develop many different configurations of sorbent traps to address those obstacles. The other key issue to understand is the importance of the sampling parameters, also referred to as the “sampling profile”, which includes selecting sampling flow rate, trap and probe temperature settings, alarm settings, and in some cases with cement plants, whether an air- cooled probe is required or not. The U.S. EPA MATS and Cement MACT rules state when using sorbent traps for compliance you must sample and analyze in accordance with EPA Performance Specification 12B (PS 12B).
Power and cement plants must also look at some additional factors to determine whether to install a mercury CEMS or a permanent sorbent trap system. Cost is one of the biggest factors and not just the initial cost of the sorbent trap system, which typically equates to about 1/3 the cost of a mercury CEMS, but the additional engineering costs mostly related to installation and running heated umbilical lines down the stack. Another factor to consider is that calibration gases are required for the mercury CEMS while the sorbent trap system has no requirement for calibration gases. These are only some of the issues to consider when choosing your mercury monitoring strategy. However, it is important to note that since the implementation of the
Author Contact Details Shawn Wood, Director of Compliance Technology, Ohio Lumex • Tel +1 (440) 264-2500 • Email:
mail@ohiolumex.com • Web:
www.ohiolumex.com
www.envirotech-online.com AET October / November 2017
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36