BuiltAir: One device. Three solutions. Ventilation, thermal comfort and indoor air quality


Heading


NosmoTech introduces its BuiltAir IEQ Monitor and explains how it can help monitor your indoor environment


We spend more than 80% of our time indoors and these built environments are one of the most important users of our global energy, but they also keep us comfortable and healthy; the three requirements are thermal comfort, good air quality and effi cient ventilation.


Two standards defi ne comfort and good ventilation for good air quality: ASHRAE Standards 55 and 62.


The built environment is complex, where good indoor air quality (IAQ), effi cient ventilation, thermal comfort and energy effi ciency all compete, demanding intelligent compromises.


Data must be collected by a network of devices, monitoring multiple zones together, giving a full picture of the building. And the measurements must be accurate.


What do we measure for IAQ and IEQ?


Indoor air quality (IAQ) requires measurements of temperature, humidity, CO2


, NO2 , PM10,2.5,1 and TVOC.


Indoor environmental quality (IEQ) requires measurement of both ambient and radiant temperature, humidity, barometric pressure, plus airspeed, noise and light.


From these measurements IEQ indices such as Heat Index (HI) and Wet Bulb Globe Temperature (WBGT) are calculated automatically by the IEQ Monitor.


Simple CO2 -temperature-humidity monitors do not provide


the required multi-parameter information to make informed decisions and solve occupants’ problems, and networked IEQ/ IAQ monitors are simply not available.


BuiltAir IEQ Monitor is a platinum standard indoor air quality monitoring system designed to deliver very accurate real- time air quality data, and alerts from offi ce buildings, schools, commercial spaces and residential and social housing.


It uniquely monitors critical parameters including: airfl ow, noise (dBA + dBC), light, CO2


, NO2 , PM10,2.5,1 , TVOC, both ambient and radiant temperature, barometric pressure and relative humidity.


The IEQ Monitor integrates with building management systems (BMS) to afford more precise ventilation control.


The IEQ Monitor has two formats – the integrated monitor has a high quality internal particulate matter (PM) monitor, while the standard device has a separate PM unit.


IEQ Monitor background


Developing an advanced IEQ Monitor required a team capable of advanced electronics, wireless and cloud competence and a deep understanding of both physical and chemical sensors.


The NosmoTech team have been developing, patenting and manufacturing air quality and water quality instruments since 1979, and developing, patenting and manufacturing low-cost gas and particle sensors (LCS) since 2005.


Founded in 2021, NosmoTech has focused on better air quality monitors for the built environment, integrating physical and chemical sensors as a sensor network. The design requirements were rigorous: lowest power consumption, best available sensors for data quality, easy calibration, fl exible confi guration, simple data visualisation, easy setup and standalone as well as network capability. Four years later, we now introduce the


As workers enter the room, CO₂ concentration increases; they then start to sand a few minutes later. As they leave, particle and CO₂ concentrations decay at different rates. Two loggers record reproducibly. The logging interval is 15 seconds.


Thermal comfort indices can only be calculated with the BuiltAir IEQ Monitor because it uniquely measures both radiant and ambient temperature, local airfl ow and humidity – all required when determining occupant comfort…or discomfort!


Environmental factors


• Air temperature – is the air too hot or cold? 0.1°C accuracy lets you trust your temperature settings


• Radiant temperature – radiant heat from surrounding surfaces, walls, windows and radiators can be very uncomfortable. A second 0.1°C sensor measures the radiant temperature. Two accurate temperatures in one device


• Air velocity – new solid state orthogonal airfl ow sensors measure the airfl ow vector, down to 0.01m/s to detect airfl ow dead spots, open window airfl ow and leakages, and those uncomfortable local drafts


• Humidity – moisture content of the air is very important to human comfort and mould growth. With 1%RH accuracy, the IEQ Monitor supports your system, ensuring your control system remains accurate and precise.


The BuiltAir monitor is affordable. Designed and manufactured in the UK by a team that understands instrument design, it achieves massive and accurate data at a cost that is not obtained by others.


Sponsored content: This article has been commissioned and placed by NosmoTech. The opinions expressed are those of the author. ILM Publications had no input into the content or reviewing of this article. This article is intended for environmental professionals.


For more information visit www.nosmotech.com.


BuiltAir IEQ Monitor, along with the BuiltAir Cloud. Whilst there are products that will monitor temperature,


CO2 and relative humidity for use in the workplace and home environments, the market was missing affordable instrumentation that records all the necessary measurements.


Where other IAQ or IEQ monitors let you down with inadequate data quality, the BuiltAir IEQ Monitor includes 12 accurate, reliable sensors delivering the data quality you need.


Airfl ow is critical to understanding the formation of mould and to provide information about the distribution of pollutants around the building. Also needed when calculating thermal comfort are indices such as Heat Index (HI) and Wet Bulb Globe Temperature (WBGT).


Barometric pressure is usually a low resolution optional extra in competitor products. The BuiltAir IEQ Monitor resolves 1 Pa for monitoring small pressure differences between zones, mapping air infi ltration and exfi ltration between zones and outdoor. Absolute pressure and the calculated pressure differences can be mapped within an entire building, using multiple BuiltAir IEQ Monitors.


Noise and light measurements inform us of occupancy and activity. Noise is recorded as both dBA and dBC, useful when diagnosing irritating background noises.


Gas, light, sound, particles- comparing different responses


With 12 sensors measuring 15 seperate parameters, comparing the response from different sensors provides a new dimension to understanding our built environment


The diagram below shows how our IEQ Monitors operate as a network.


Using thread network technology (as used by Amazon Alexa and Google), each monitor communicates with the router, which the wi-fi links to the BuiltAir Cloud for data compensation, analysis, vaulting and downloading.


Monitoring applications


•Interfacing with your Building Management System (BMS), the IEQ Monitor communicates with control software to provide data for supporting ventilation control, ensuring thermal comfort and optimising energy usage


•Controlling mould and damp in social housing is important for both health and well being and building maintenance. High humidity corners and poor airfl ow are ideal conditions for mould growth. Continuous networked monitoring lets building managers identify the conditions or activities that are causing the problem


•School and public building ventilation is often old or poorly maintained, with little funding to install new HVAC systems. Poor ventilation results in reduced cognitive performance and potential damp and mould growth leading to health problems. School improvement grants are available for schools if they can illustrate the need due to poor ventilation airfl ow, temperature and relative humidity


•While workplace exposure is concerned with monitoring within the breathing zone, continuous area monitoring is a useful tool, especially when there are worker complaints or new machinery or processes. Monitoring good ventilation with CO2


, plus monitoring particles, NO2 and VOCs, the


primary pollutants, ensures compliance and comfortable and safe workers.


ii


IET - JANUARY / FEBRUARY 2026


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60