Measurement and Testing 49 Solving the Issues when Measuring Food, Powders, Cosmetics and Pastes


The new Lovibond LC 100 / SV 100 combination from Tintometer, is the ideal solution for the versatile communication of colour measurement. By housing the spectrocolorimeter in a uniquely designed stand, samples can be read at an ergonomic viewing angle, enabling the measurement of ‘awkward’ substances in Lovibond optical cells. A secure cap is provided to cover the sample, protecting it from any excessive ambient light, enabling quick yet accurate readings.


The Lovibond LC 100 colorimeter enables setting and maintaining colour standards throughout the manufacturing process. It is a lightweight tool that is easy to handle and ready to use. In just over a second, it not only provides a reading of the sample but also a report telling how close the colour is to a measured standard. Users can create and measure against up to 20 self-programmable standards with a default average valuing of 3. The LC 100 automatically creates conformance reports in either PDF or Excel formats for each stored sample against each standard. These can easily be shared with a PC or directly to a compatible printer (via USB mass storage mode).


Stand-alone, the SV 100 is a very portable, quick yet accurate tool for colour measurement. However, it is the precision-designed Lovibond accessory kit that makes it so flexible. Supplied with the stand and cap to remove ambient light and 10 Lovibond 10ml cells, the instrument is now ideal for the colour measurement of food, powder, cosmetics, pastes and pharmaceuticals.


Reader Reply Card No 157 New Digital Controllers for General Application


WIKA (Germany) has now completed its portfolio of temperature controllers with two digital instruments for simple thermostat applications: The model SC58 and model SC64 close the gaps in this segment between mechanical products and complex PID instruments.


The new digital controllers are designed for a measuring range of -80 to +400 °C, and can therefore be used universally. The switch hysteresis can be set via the menu, which assists the flexibility. Both two-point controllers are equally notable for their high switching accuracy and contact rating (16 A). They are easy to use and offer a highly-visible display (13 mm high characters).


The SC58 and SC64 have the same design as the corresponding mechanical and mechatronic controllers. Users can therefore change to the digital instrument without any additional expense. Reader Reply Card No 158


Mars Rover Curiosity Equipped with Pressure and Humidity Sensors


pH Measurement and Correction of H2S for Waters


Refex (Europe) have designed their reference sensors for arduous applications particularly where fouling or poisoning conditions exist. The sensors use a highly stable non-porous polymeric interface in place of the traditional porous liquid junction used by other conventional reference electrodes.


With Refex reference sensors, the active reference area is the whole of the outside surface of the electrode; this super large contact area means that the electrode is supremely resistant to coatings.


One major problem with all pH/mV electrodes is the porous/leaking reference junctions rapidly failing. The main issue being the


poisoning of the porous junction and KCl electrolyte. This happens by H2S back-diffusing through the porous junction. H2S reacts with the Ag/AgCl (silver/silver chloride) half cell and forms AgS - this precipitation occurs in the porous junction that destroys the mV stability. This degradation happens immediately after the electrode is installed and within a few days/weeks the electrode will be useless.


The Refex electrode is exceptionally resistant to applications containing poisons such as cyanide, ammonia and sulphides. This immunity is achieved because the polymeric reference is ionically conductive but not porous and prevents elements of the process from contaminating the electrode causing drift and inevitable failure.


The Refex electrode with the unique and patented Solid-State Non Porous Reference Retrofits to the Yokogawa flow cell and connects directly to the Yokogawa connecting cable. They are also compatible with Emerson cables, typically the 399 and 381 systems.


Refex electrodes often last 5-10 times longer than current electrodes and Refex are currently offering new customers a TRY-IT / BUY-IT free 90 day evaluation. Reader Reply Card No 159


As NASA's Mars Curiosity rover is examining the soil in the Gale Crater to see if it ever offered conditions favourable for supporting life, Vaisala's (Finland) pressure and humidity sensors onboard the rover are also hard at work. The sensors are on Mars as a part of instrumentation designed by the Finnish Meteorological Institute (FMI), and they are used to gather pressure and humidity readings in the extreme environmental conditions of the Martian atmosphere.


Vaisala has provided the project with standard Vaisala HUMICAP humidity sensors and specially customised Vaisala BAROCAP pressure sensors. First introduced in 1973, Vaisala HUMICAP was the world's first thin- film capacitive humidity sensor and a radical innovation that changed humidity measurements for good. Similarly, Vaisala BAROCAP was developed in early 1980s as a new pressure-sensing technology based on silicon processing.


Both sensor technologies are used widely in Vaisala's own humidity and pressure sensing products and systems. Thanks to their superior long-term stability and accuracy as well as their ability to tolerate dust, chemicals and otherwise harsh environmental conditions, the technologies are especially suitable for demanding industrial applications used by a wide range of industries from power and steel to life science and building automation.


Reader Reply Card No 160


NEW PROCESS


NMR ANALYZER revolutionizes


on-line petroleum analysis Modcon Systems Ltd.


145-147 St John Street London EC1V 4PW UK Tel: +44-207-5043626


www.modcon-systems.com analyzer@modcon-systems.com


Reader Reply Card No 161 Annual Buyers’ Guide 2013 • www.petro-online.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96  |  Page 97  |  Page 98  |  Page 99  |  Page 100  |  Page 101  |  Page 102  |  Page 103  |  Page 104