MEASUREMENT & TESTING New solution to eliminate the need for manual water quality testing
Ketos has announced that its Ketos Shield solution now provides operators with lab accurate results for over 20 water parameters. Ketos Shield is part of a fully integrated water analytics solution, giving operators access to automated reporting, real-time alerts, custom threshold-based diagnostics, custom reports, historical trends, and mission-critical insights by continuously analysing water data in conjunction with advanced machine learning.
These insights are vital for the public and private sectors and are used for water quality, safety assurance testing, protecting liability, understanding process optimisation in industrial plants, improving crop yields and water data for farming, besides overall consumer health.
“Ideal for high-frequency water quality sampling, the Ketos Shield solution is offered as a complete end-to-end service for a flat fee,” said Meena Sankaran, CEO of Ketos. “This reduces the complexity of having multiple vendors and integrators for hardware, communications, software, and maintenance, and it gives organisations the opportunity to allocate budget in a way that best suits their needs.”
The highly user-friendly Ketos Shield eliminates the need for manual water quality testing and reduces the need for manual equipment cleaning, calibration, or maintenance on a daily/weekly basis. Its precision, sensitivity, and data accuracy is comparable to 3rd party labs so that users can leverage data for applications such as process control, nutrient management, drinking water safety, or water reuse. Ketos Shield also features an early warning system in real- time to enable users to measure, manage and monetise water as a resource as well as real-time data visualisation with predictive intelligence.
For More Info, email: email:
For More Info, email: email:
55236pr@reply-direct.com
What presentations will be given at the PEFTEC conference?
A new revolution in pressure testing and calibration
The organisers of PEFTEC the conference and exhibition for the Petroleum, Petrochemical, Chemical and Refining Industries are pleased to announce a leading team of experts have joined their Scientific committee. Anupam Giri lead Scientist at Sabic and Analytical Conference Chair and Edo Becker Process Chair of PEFTEC have invited a well-balanced mixture of Industry scientists from Total, BP, Dow, Borouge, BASF with leading researchers and academic experts to join the conference team.
Marcus Pattison organiser of PEFTEC says this conference committee will bring a vast wealth of technical experience and end user interest to the program. Topics that will be discussed at this years’ conference will include.
• Advancement in Petroleomics: Chromatography, Spectroscopy, Thermal & Elemental analysis
• Analytical challenges in addressing new generation Fuel/Feedstocks and renewables • Automation in analysis, hyper-fast or rapid technologies • Chemometric applications in big data analysis
• Comprehensive technology (2D GC, 2D LC) applications for supporting refineries, steam cracking, fast pyrolysis, scale-up, fouling etc
• Data fusion of PAT with other plant and analytical data for optimisation of plant parameters
• Developments in the areas of PAT for Process 4.0 and their implementation in the industry • Developments of digital twins • Emerging technologies • High-resolution mass spectrometry and other novel detectors • Inferential Measurement • Molecular characterisation & Identifying ‘Know-Unknown’ chemicals • New developments in robust sampling of process fluids for reduced maintenance
• Novel types of PAT sensors (Technologies, Robustness, Sensitivity, Wireless Connectivity and Miniaturisation)
• Novel chemometric methods and data analysis • On-Line Chromatography and Spectroscopy • Plant PAT sensor networks and swarm interaction • Remote monitoring and maintenance assistance • Use of cloud computing for PAT data analysis and standardisation
The PEFTEC Virtual conference and exhibition is scheduled for the 24th & 25th November 2021 with the follow up Live event booked for June 2022 in Rotterdam for more information about PEFTEC please contact us today.
More information online:
ilmt.co/PL/vq3M For More Info, email:
email: For More Info, email: email:
55408pr@reply-direct.com
WWW.PETRO-ONLINE.COM
email: For More Info, email: email:
The Ralston Instruments FieldLab is a revolutionary pressure device for testing and calibration. Tests can be created for datalogging, pressure calibration, pressure safety valve testing and hydrostatic testing. Create a test on a PC using the included FieldLab Desktop software and put it to one or more FieldLabs or run the test from a PC. On-screen prompts lead the user through a test and tell them right on the FieldLab whether the device under test is out of tolerance. Easily download data onto a PC for for creating calibration certificates. With pressure ranges from 30 psi to 10,000 psi (2 to 700 bar), certified for Class I Div 1 and ATEX / IECEx Zone 0 Hazardous locations, measurement uncertainty of 0.1% of reading, temperature compensated, lithium-ion rechargeable battery and a color screen the FieldLab Pressure makes an indispensable addition to any pressure test or calibration kit.
More information online:
ilmt.co/PL/2XAj For More Info, email:
New advanced NIR portable fuel analyser
Zeltex, LLC announces the latest in their line of ZX-101 Portable Fuel Analysers, the ZX-101SQ. The ZX-101SQ combines the proven reliability and lab accuracy of the previous model, the ZX-101XL, that thousands of customers currently rely on. The SQ is upgraded with improved Near Infra-red optics (NIR) as well as a much easier user interface. Quickly analyses for octane, cetane, percent ethanol, and biodiesel percentages. This new analyser will enable you to get fast sample analysis to determine your fuel quality at the pump, in the field, or in the lab.
email: For More Info, email: email:
The ZX-101SQ has an increased wavelength range for more accuracy with biodiesel and ethanol analysis with improved (14 to 16) calibrations and accuracy (particularly for Biodiesel). This instrument’s optical range has been increased to (810nm – 1045nm) from (893nm – 1045nm) with the previous models in the range. This analyser also includes an automatic fuel type detection option which reduces operator error, a 2-piece filter tray (not one piece) adds longer filter life span (approx. 25 y) and the larger colour display with graphic instructions and the enhanced user interface and printer controls further improve the ZX-101SQ’s ease of use. Zeltex have also expanded the memory of stored, analysed samples from 25 to 100 samples having integrated a next generation computer board. This unit is protected by a Pelican military-spec carrying case and a 1-year warranty is standard.
More information online:
ilmt.co/PL/gpel For More Info, email:
54529pr@reply-direct.com
53910pr@reply-direct.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44