Analytical Instrumentation 27


One Rheometer, Two EC Motors, All Possibilities


Anton Paar (Austria) introduces a rheometry revolution: MCR 702 with modular TwinDrive technology. This is the world’s first rheometer to cover all possible rheological applications – with an accuracy of 1 nNm and features like the IsoLign Piezo flange, offering measuring gap control down to an unprecedented size of 10 nm.


Anton Paar’s TwinDrive technology combines two powerful synchronous


EC (Electrically Commutated) motor units in a modular setup: The upper EC motor in the rheometer is permanent; the lower EC motor can be extracted and integrated at will. Due to the EC motor's renowned dynamism and precision, users have several options of how to employ these motor units to fit their specific requirements.


MCR 702, the first rheometer with fully integrated TwinDrive technology, can be operated in several test modes and covers all rheological applications – past, present and future.


In this mode, the rheometer employs both EC motors as drive units and torque transducers, optionally rotating in opposite or parallel directions. Doubled EC motors extend the scope of testing options, e.g. with optional counter-rotation for enhanced rheo-microscopy. MCR 702 TwinDrive can be operated with both motors’ maximum shear rates combined and is optionally employed for extensional rheology applications or tests with parallel rotation at different speeds.


The 2EC mode also enables users to employ the motors in a more synchronised fashion, making “different demands” on each of them. Because of the EC motors’ outstanding precision, one motor is easily brought to a standstill and operated solely as a torque transducer, while the other motor is used as a drive unit only. This turns MCR 702 into the best available separate motor transducer rheometer for rotational and oscillatory tests, at the unprecedented torques and normal forces offered by Anton Paar’s EC motors only.


In the EC mode, the lower motor unit is easily removed in accordance with individual application needs. This procedure is fully supported by Toolmaster, the MCR’s automatic tool recognition and configuration system. After the extraction of the lower motor, the instrument can be operated as a single-drive rheometer, making the most of the single EC motor’s TruStrain capability and enabling “classic” stress-controlled tests. The EC mode opens MCR 702 up to the wide variety of custom-tailored temperature devices and application-specific accessories the MCR series is famous for.


MCR 702 TwinDrive is the first rheometer to offer nano-scale precision on several counts – such as low-torque measurements down to a minimum of 1 nNm and the control of angular deflections down to 100 nrad. Now this peak precision also extends to the system’s measuring gap control: The new IsoLign Piezo flange performs gap size changes as small as 10 nm. Based on a system of 3 Piezo elements in the flange of the measuring chamber reception, IsoLign is reliably employed in all TwinDrive test modes.


The rheometers from Anton Paar can be operated either in the 2EC mode or in the EC mode and open up entirely new measurement dimensions. One rheometer, two EC motors, all possibilities.


Reader Reply Card No 93


New Video Demonstrates Cool-Lock® Nut for GC Column Installation


Phenomenex Inc. (USA), a global specialist in the research and manufacture of advanced technologies for the separation sciences, have announced a new online video demonstrating installation of the company's Cool-Lock Nut. The unique Cool-Lock Nut ensures precise and painless GC column installation and eliminates the need for wrenches or other tools. The low thermal mass design allows the Cool-Lock Nut to cool rapidly, preventing users from burning their fingers during column changes. Other unique design elements prevent the column from slipping to ensure a more reproducible installation depth for improved method accuracy. The short online video guides users through the quick installation process.


Expect


"Because this product is unique, it's helpful to see a quick demo on the installation process," explained Kristen Parnell, brand manager of GC products for Phenomenex. "Method sensitivity losses of up to 30 or 40 percent are common when columns are not installed at the optimal depth. It's difficult to ensure exact positioning because the work space is cramped and the materials are quite hot. The Cool-Lock Nut allows users to change a column very quickly without burning their fingers, while helping to improve installation accuracy and reproducibility."


The Phenomenex Cool-Lock Nut works with all standard GC columns and is compatible with Agilent and Shimadzu GC systems. The Nut is available in both long and short ferrule dimensions and can be used over and over for accurate column installations.


Reader Reply Card No 94 essentials


The Power of Thermodynamics™


The new PRESTO®


Highly Dynamic Temperature Control Systems. Powerful pumps. Working temperature range of -92 °C to +250 °C. Robust and reliable in ambient temperatures up to +40 °C. Straightforward operation and monitoring with a color industrial grade touch screen. What more could you ask for?


Karl Fischer Moves Out of the Laboratory


At the recent Pittcon exhibition & Conference held in Philadelphia, GR Scientific (UK) gave a presentation entitled “Karl Fischer Moves Out of the Laboratory ”.


The presentation clarified the differences in the volumetric and coulometric Karl Fischer techniques and explained how recent innovations and product designs enable these instruments to be used in the field just as accurately as they are in the laboratory.


Email info@grscientific.com for a free flash drive containing this presentation, and additional technical information.


Reader Reply Card No 92 Superior Temperature Technology for a Better Life


Exceptional performance in design of process engineering systems and pilot plants for the petrochemical industry:


 


  


 apparatuses


i-Fischer Engineering GmbH Dachdeckerstr. 1 97297 Waldbüttelbrunn Germany


Tel.: +49 [0] 931-46 79 7-0 Fax: +49 [0] 931-46 79 7-29 E-mail: info@i-fischer.de www.i-fischer.de


technology  i-Fischer Engineering GmbH www.julabo.de Reader Reply Card No 95 Reader Reply Card No 96


APRIL / MAY 2013 • WWW.PETRO-ONLINE.COM


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52