HEATING, VENTILATION & SERVICES


Optimum technologies for future-proofing homes


Architects can please builders, benefit end-users, and be kinder to the environment, by keeping up to speed with innovations in home heating, as Christian Engelke of Viessmann explains


T


he architect’s responsibility to future- proof homes for inhabitants – at the same time as keeping construction


costs down – isn’t always easy. This is certainly a challenge when deciding upon technologies for indoor climate control. The optimum options for energy efficiency, minimally disruptive mainte- nance, or ease of installation, are changing fast. Space-heating solutions can no longer be unthinkingly repeated from one job to the next without questioning whether they’re still the best. The most popular of all domestic heat generators, gas condensing boilers, are a perfect example of this. Here are five future-proof technical features that environmentalists, end-users, installers and maintenance engineers will all appreciate.


New push-fit connections for quicker installation time


It’s not only materials that cost money in house-building, but also labour. That’s why architects’ clients – builders – love labour- saving processes, and why they’d be glad to know that new tool-free push-fit systems now provide a boiler for operation in just five simple steps. By installing the boiler on the bracket of an installation jig, all heating water and domestic hot water pipes are already securely connected to the network without the need for clamps or soldering, and the only threaded fitting necessary is in the gas connection.


Self-calibrating automatic combustion controller


It’s now also possible to eliminate the need to manually change the gas valve or gas injector if the boiler has to be changed over from natural gas to liquefied petroleum gas using automated controllers. These labour- saving benefits are gained by specifying a boiler with a self-calibrating automatic combustion controller.


Smart energy management


The integral control units of domestic boilers are beginning to give information detailed enough to help control energy consumption. Recent innovations include easy-to-use touchscreens providing contin- uous information about gas consumption and boiler power. Because historic data is easily retrievable, it can also be used to modify user habits and reduce energy costs.


Automatic flue gas adaptation


This feature ensures optimum boiler performance by adapting to variations in ambient air pressure. This matters because air flow into a boiler is affected by ambient air temperature and long flue runs, and adverse wind conditions can prevent the boiler from running at its desired output. Now there’s a sensor that detects these fluctuations and adjusts the fan speed accordingly, ensuring that the boiler always runs at 100 per cent when required.


Dynamic pause time optimisation


A boiler’s burner typically remains off after each operating cycle until a minimum time period has elapsed and the boiler water temperature has fallen below a predefined limit. This is known as the pause time. With dynamic pause time optimisation, however, an algorithm evaluates the rate at which the boiler water temperature increases during the switching interval, then matches pause times to this. This results in fewer cycles and pre-purge phases, extending burner runtimes during spring and autumn – and that means lower standby losses due to low average boiler water temperatures; improving efficiency, reducing energy consumption, and lower- ing emissions.


Christian Engelke is technical director at Viessmann


Space-heating solutions can no longer be


unthinkingly repeated from one job to the next


61


ADF JANUARY 2018


WWW.ARCHITECTSDATAFILE.CO.UK


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76