CABLING & CABLE MANAGEMENT FEATURE Time for some definition


When it comes to cable protection it is important to be specific so that you know exactly what your cable is capable of. Here, Ian Gibson, technical director for Flexicon, claims that terms such as ‘weather-proof’ and ‘suitable for outdoor use’ are just too vague


T


he claim that a product is suitable for outdoor use or provides protection


from the weather is a term that is laden with potential pitfalls. When it comes to the weather there are a multitude of different factors to consider, not least because the weather varies dramatically from country to country For Flexicon this is a daily quandary since


cable protection is often required outdoors for any application requiring power and data. It may include applications as diverse as CCTV cameras, solar panels and boats. Flexicon’s flexible conduit systems are used all over the world and in climates as diverse as the desert, the Arctic, the Himalayas and under the ocean. It is therefore important to get the specification right because a material’s properties will change as it conditions to the weather around it. The only sensible approach is for the specifier to make a full risk analysis to identify what hazards the cabling may need protecting from.


IP RATINGS When thinking about the term weather- proof most people would probably start by considering the IP rating. Starting with dust ingress, as far as conduit systems are concerned you should set a minimum level of IP5x where dust will not enter the system in harmful quantities and better still 6x which means that dust will not enter at all. Protection against water ingress is more


complicated. Potentially ingress could come from rain, spray, possible immersion plus capillary action and suction caused by the rise and fall of temperature. Using a vented conduit system, which allows the air inside the enclosure to expand and


contract with temperature changes, can prevent the latter action. You should also treat the IP rating system with caution, because the tests are over the short term on samples that the manufacturer has assembled under ideal conditions. In practice the flexible conduit may be exposed to a constantly changing environment over several years. With the latter point in mind BS EN IEC 60529 states that above IPx6 you cannot assume that the product will meet a lower level. This is because when you look at each of the tests you will see that each is a different type of test and subjected to different conditions and environments. The specifier should take a belt and braces approach to prevent water ingress over the lifetime of the installation. You should specify a minimum level of IPx6 plus IPx7 if you do not know the orientation of the conduit fittings. If, however, the installer assembles the fittings on the underside of an enclosure then you may find that IPx5 or IPx6 is suitable. You should also check what material


the conduit is manufactured from, since nylon conduit and fittings will attract and absorb water. When it is wet a nylon conduit system will become more flexible with better impact strength and fatigue life but lower compression strength. In dry conditions the opposite will happen.


Above: Ian Gibson, technical director for Flexicon


Left: Flexicon cable protection is often required outdoors for any application requiring power and data. It may include applications as diverse as CCTV cameras, solar panels and boats


Below: protection against water ingress is complicated. Potentially ingress could come from rain, spray, possible immersion plus capillary action and suction caused by the rise and fall of temperature


UV DEGRADATION Another variable factor depending on location, climate and altitude is the affect of UV radiation - which will degrade plastic materials and result in lower impact strength, less flexibility and a lower fatigue life. To resist the effects of the sun, check that product has carbon black added, which protects the polymer chains. As an indication, where Flexicon describes a product as ‘UV resistant’ there is enough carbon black added to ensure UV resistance around the world. You should check what a manufacturer


means by UV resistant and ask whether there is any independent test results that can be used to verify the claim. Flexicon has tested numerous products to UL1660 test criteria for weather resistance. There are ways of making other colours UV resistant, such as by adding a chemical UV resistant additive.


TEMPERATURE Generally it is low temperature that may cause an issue and you should check that the conduit has a low enough minimum operating temperature to prevent damage by impact or bending during installation or use.


OTHER FACTORS There are of course a number of other factors that you should consider in relation to the outdoor environment. These may well vary according to the application. For wind turbine applications, for example, one of Flexicon’s conduit systems has been tested to withstand the effect of a direct lightning strike. You may also need to protect the system against vandalism and/or attack by animals. Flexicon has even had to produce Cockatoo-proof conduit for an application in Australia. The problem with the term weather-


CORROSION RESISTANCE Corrosion is another issue that needs considering in relation to water. Coated steel conduits will be suitable as long as the IP rating is sufficient to prevent water ingress. Grade 316 stainless steel fittings are probably best used since nickel plated brass fittings will discolour through oxidation overtime, particularly in coastal areas due to salt spray.


/ ELECTRICALENGINEERING


proof is how you define it. Climates change in different locations and even from season to season. It is a lazy term that should probably not be used - rather the specifier should define what hazards the conduit will face.


Flexicon www.flexicon.uk.com T: 01675 466 900


Enter 206 ELECTRICAL ENGINEERING | SEPTEMBER 2014 19


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64