Miscellaneous
RS-485 Conversion Module CA-A360-USBRS
Uses UTP cable (Cat 5).
Input voltage: 12V dc.
On-board end-of-line (EOL) and bias jumpers.
Lock Control Module CA-A110-P
Connects directly to the terminal blocks of the CT-
V900-A.
Fire-alarm switches. Instant unlocking of the doors. Simplify the installation of dual-locking doors (2
magnetic locks or one magnetic lock and one electric strike).
2 Form “C” lock outputs (5A/12V dc NO/NC).
2 relay status LEDs.
4 Port RS-485 Network Hub without Box CA-A370-PNB
costs.
RS-485 “Star” configuration is a snap.
Provides higher network isolation and reduces wiring LED status indicator for power, network and port activity.
485 network.
Creates 4 independent RS-485 networks from one RS- Connects to the CT-V900-A RS-485 and E-bus
communication ports and to the E-Bus for the expansion modules.
from the Hub.
Also available
Connects controller or expansion module up to 1220m Transmission speed: 9600 or 19200 bps.
CA-A370-P - With Box
2-door Expansion Module without Metal Box CA-A470-ANB
CA-A470-A - With Box
Also available
Tracker LCD keypad Module CK-TRAK-L
bus.
card locations.
Supports multiple language displays.
Display for the time and attendance.
Connect up to 8 keypads to the CTV-900-A controller E- Can be used with anti-passback applications to display Input voltage: 9 to 16V dc.
4 inputs (door contact and REX devices
Input voltage: Transformer, 16V ac/40VA (TR16/40)
6 reader outputs (red/green LEDs and buzzer) E-Bus connectivity to the CT-V900-A up to 1220m
Lock outputs: 2 Form "C" relays dry Contact, 5A/30V dc
NC/NO
Add 2 doors to the CT-V900-A or 2 readers and/or
keypads
Up to 3 CA-A470-A modules per CT-V900-A
Relay Expansion Module without Box CA-A460-PNB
controller.
Maximum of two CA-A460-P modules per CT-V900-A
controller.
1220m.
CA-A460-P - With Box
Also available
Destination Reporting Module CA-A482-P
Connects directly onto the CA-A480-A lift controller.
One-card swipe, one-floor operation.
A480-A.
Input response time: 700 ms.
Input voltage: 5V dc
DC input activation: 15V dc (min), 165V dc (max).
TCP/IP - RS-232 converter CA-ETHR-A
RJ-45 connection to the LAN.
mbps - half duplex.
RF Receiver RECEPT W
Output: 26 and 30-bit wiegand
1 channel, Rolling Codes, 433 MHz
Range up to 100 meters in open field
Ethernet compatibility: Version 2.0/IEEE 802.3. 10
9600, 19200 and 38400 serial bauds rates.
Supports TCP/IP, HTTP, ICMP and ARP protocols.
Comprehensive LED status indicator. RS-232 serial connector supplied.
Static IP addressing.
Converts the TCP/IP protocol to RS-232. Simple programming and setup.
Registers valid and invalid floor selections.
16 floor-selection inputs and LED indicators. Connection method: Flat 14-strand cable to the CA-
Connects directly to the CT-V900-A expansion bus. Connects to the controller at a maximum distance of
Input voltage: 12V dc.
Outputs: 7 Form C relays rated at 5A/28V dc, NC/NO. Adds 7 form-C relay outputs (NO/NC) to the CT-V900-A
Eliminate Faults & Call Backs!
ADI has a full array of Test Sets, Tone Generators and Fault Finders so that you can feel confident that you have given your customer 100% satisfaction in the work you performed.
130 Sales and Support, Call: 1300 ADI ADI Technical Support, Call: 1800 220 345
www.adiglobal.com/au
Access
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126 |
Page 127 |
Page 128 |
Page 129 |
Page 130 |
Page 131 |
Page 132 |
Page 133 |
Page 134 |
Page 135 |
Page 136 |
Page 137 |
Page 138 |
Page 139 |
Page 140 |
Page 141 |
Page 142 |
Page 143 |
Page 144 |
Page 145 |
Page 146 |
Page 147 |
Page 148 |
Page 149 |
Page 150 |
Page 151 |
Page 152 |
Page 153 |
Page 154 |
Page 155 |
Page 156 |
Page 157 |
Page 158 |
Page 159 |
Page 160 |
Page 161 |
Page 162 |
Page 163 |
Page 164 |
Page 165 |
Page 166 |
Page 167 |
Page 168 |
Page 169 |
Page 170 |
Page 171 |
Page 172 |
Page 173 |
Page 174 |
Page 175 |
Page 176 |
Page 177 |
Page 178 |
Page 179 |
Page 180 |
Page 181 |
Page 182 |
Page 183 |
Page 184 |
Page 185 |
Page 186 |
Page 187 |
Page 188 |
Page 189 |
Page 190 |
Page 191 |
Page 192 |
Page 193 |
Page 194 |
Page 195 |
Page 196 |
Page 197 |
Page 198 |
Page 199 |
Page 200