Potterton Commercial


Product name - fuel type - boiler type - output range - maxium gross effi ciency - NOx emissions - size (w) x (d) x (h)


Tel: 0345 070 1055 Web: www.pottertoncommercial.co.uk 115kW: 480 x 585x 851mm


Sirius three WH – Natural gas/LPG – condensing wall-hung – (kW) 50, 60, 70, 90, 110, 130, 150 – 97.3% – 17-36.5 mg/kWh NOx – 50-70kw: 450 x 377 x 766mm; 90-150kW: 600 x 584 x 952mm


Sirius three FS – Natural gas/LPG – condensing fl oor standing – (kW) 50, 70, 90, 110, 130, 150, 200, 250 – 97.5% – 17-39.5 mg/ kWh NOx – 50,70kW: 600 x 681 x 905mm; 90,110,130,150kW: 600 x 681 x 1127mm; 200,250kW: 600 x 1412 x 1238mm


COMMERCIAL SUPPLEMENT


BOILER


Address: Innovation House, 3 Oaklands Business Centre, Oaklands Park, Wokingham, RG41 2FD


NXR4i – Natural gas/LPG/oil/dual fuel – pres- sure jet fl oor standing – (kW) 419, 481, 543, 605, 667, 729 – 83% natural gas – 85% oil – NOx level dependent on burner specifi ed – 419kW: 1000 x 1950 x 1500mm; 481kW: 1000 x 2120 x 1500mm; 543kW: 1000 x 2305 x 1500mm; 605: 1000 x 2425 x 1500mm 667kW: 1000 x 2625 x 1500mm; 729kW: 1000 x 2785 x 1500


3500kW: 1970 x 3879 x 2271mm; 4000kW: 1970 x 4279 x 2271mm


Unique selling points


Our Sirius cascade frame kits which can accom- modate up to six boilers, spreading heat demand across multiple boilers.


Sirius FS – Natural gas/LPG – condensing fl oor standing – (kW) 400 & 525 – 97% – 26 mg/kWh NOx – 400kW: 590 x 1341 x 1405mm; 525kW: 590 x 1558 x 1405mm


Eurocondense Four – Natural gas/LPG – con- densing fl oor standing – (kW) 125, 170, 215, 260, 300, 430, 520, 600 – 95% – 39mg/kWh NOx – 125kW & 170kW: 692 x 1008 x 1389mm; 215kW: 692 x 1171 x 1389mm; 260kW: 692 x 1264 x 1389mm; 300kW: 692 x 1357 x 1389mm; 430kW: 1434 x 1171 x 1389 mm; 520kW: 1434 x 1264 x 1389mm; 600kW: 1434 x 1357 x 1389mm


NXR5i – NG/LPG/oil/dual fuel – pressure jet fl oor standing – (kW) 810, 870, 930, 990, 1055, 1100, 1160, 1200, 1280, 1340, 1400, 1460 – 84% effi ciency natural gas – 88% effi ciency oil – NOx level dependent on burner specifi ed – 812kW: 1172 x 2538 x 1805mm; 870kW: 1172 x 2649 x 1805mm; 928kW: 1172 x 2760 x 1805mm; 986kW: 1172 x 2871 x 1805mm; 1044kW: 1172 x 3071 x 1805mm; 1102 kW: 1172 x 3128 x 1805mm; 1160kW: 1172 x 3279 x 1802 mm; 1218kW: 1172 x 3390 x 1805mm; 1276kW: 1172 x 3501 x 1804mm; 1334kW: 1172 x 3612 x 1805mm; 1400kW: 1172 x 3723 x 1805mm; 1450kW: 1172 x 2834 x 1805


Paramount four – Natural Gas/LPG/Oil/Dual Fuel – condensing wall hung – (kW) 30, 40, 50, 60, 80, 95, 115 – 95% – 21-30mg/kWh NOx – 30kW & 40kW: 480 x 407 x 851mm; 60kW: 480 x 447 x 851mm; 80kW: 480 x 542 x 851mm; 95kW &


Arizona Evolution – Natural gas/LPG/oil/dual fuel – pressure jet – (kW) 1320, 1570, 1850, 2200, 2650, 3000, 3500, 4000 – 82% gas – 84% oil – NOx level dependent on burner specifi ed – 1320kW: 1352 x 2686 x 1540mm; 1570kW: 1462 x 2781 x 1650mm; 1850kW: 1462 x 3151 x 1650mm; 2200kW: 1622 x 3225 x 1810mm; 2650kW: 1622 x 3545 x 1810mm; 3000kW: 1720 x 3835 x 1990mm;


They have adjustable mounting feet which makes them safe and stable on uneven surfaces.


They are compact and their modular fl oor stand- ing framework saves space and reduces installa- tion time.


They have a hydraulically sized fl ow and return manifolds which match the total designed fl ow rate, whatever the system load.


The robust installation kits for fl ow and return headers minimise heat loss. The steel gas manifold pipework is robust.


The hydraulic system manager, which includes air, dirt and magnetic fi ltration and fl ow manage- ment, protects the boiler’s components by ensuring a clean system and water, and removes air as well as preventing noise.


Brief company history Country of origin: UK Founded in 1850 No. of employees: 6,500 across Europe


Mission statement: Creating lifetime customer loyalty.


CaseStudy


The Victoria Hotel in Sidmouth promises guests: “from the moment you step through the original carriage portico, you will be surrounded by warmth and refi nement.” Where the exquisite décor and four-star service provides the refi nement, a new A-rated effi cient boiler from Potterton Commercial is providing the warmth. With such a pledge to live up to, this year, the hotel had to act fast to replace its outdated and ineffi cient heating system with a new Potterton Commercial Sirius boiler. The hotel had some key requirements for its new heating system. It required a boiler that fi tted within the limited footprint of the existing plant room on the ground fl oor. There also had to be some form of back-up in case of a heating system failure. Marc Coombes of Sidmarc, who has worked with the hotel group for two decades, was brought in to survey the property. After


conducting a thorough analysis of the building, he concluded: “The hotel needs 300kW of energy to operate effi ciently. With this in mind the options were that we could have three smaller boilers, or go for the latest dual burner technology that could replace three existing boilers with one to save space, without compromising on performance, energy effi ciency or redundancy.” The Sirius FS 400kW was perfect for the Victoria Hotel due to Its leading modulation ratio; variable heating requirements, to optimise energy effi ciency and running costs; being equipped with a weather sensor as standard, so the boiler’s output can vary according to outside conditions; being perfect for hotels with fl uctuating occupancy rates and heating loads; and, fi nally, having the technology to lower a building’s energy consumption and carbon footprint.


www.heatingandventilating.net


September 2018


S11


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64