www.heatingandventilating.net


Fan coils


FCU TRIED & TRUE A


requirements of the most demanding building The EVO270 is said to meet the heating and c heating and cooling across th space and the 605 FCUs prov The building has been design London at The Brunel Building, construction of a new o


t tion of a new o coil units (FCUs) have bility Projects has announc


nounced that its EVO270 fan


ned to offer high quality office ng, 2 CanalsideWalk, London. office building by Derwent been installed in the


vided by Ability will supply


et the heating and cooling he 15 floors.


The result of several years research and development, the to the requirements of BB101: 2018.


ensuring recommended indoor air qualities (IAQ) are achieve The Smart-Vector range of fresh air fan convectors offer f


standing top outlet model SV88; high wall model SV53; ceilin There are five models in the Smart-Vector range: floor sta to encourage good distribution of air and low noise levels. recommended that two units operating together as a master heating using a stand-alone controller with local setpoint ad or building layout is restrictive. Smart-Vector provides dema


ese products offer a proven solution


ed when project budgets are limited urther options to the client,


r and slave be installed in the space justment. In larger classrooms, it is and-led tempered fresh air and


anding front outlet model SV19; floor ng mounted SV80 and a floor


air volume (VAV) control function, it is recommended that the units ar achieved by good air circulation. As the air turnover rate thro With nominal outputs ranging from 1.4kW to 14.6kW, comf standing ducted tall cabinet front outlet model SV22.


Smart-Vector stand-alone and master units are supplied with a w turnover rate of four air changes per hour at design duty.


low temperat unit. Stand-a infinitely adjustable so as to attain the necessary air flow w port valve and actuator, energy efficient EC (brushless DC) Each unit is complete with a frost protection thermostat the controller can be integrated into a Modbus or BACnet BM noise level and low CO2 levels, whilst achieving the desired a outputs to control the fan, damper and control valve, enablin controller with integral CO2 and air temperature sensors. Th


ough the unit varies with a variable fortable conditions in the space are


e units are selected to give an air


ambient temperature. In addition, ng minimum use of energy, low he controller provides modulating with a wall mounted digital


MS. and spring return actuator, 2 or 4-


ture cut-out (LTC) thermostats to LT lone and master units also have without excessive noise on each motor. Maximum fan speed is


BMS system is not being instal controlled ind projects that r cooling. Sma and allows bu conjunction w The Smart unoccupied p p


The Smart-Vector fan convectors


stand-alone s will provide b a pre-pur


e purge p managers, us initiate temp erature set-back during


with the Smart-Vector controllers -Vent controller is used in periods.


rt-Vent is specifically designed for uilding managers to enable free


dependently, where a dedicated require up to 32 rooms to be


is not being installed.


In addition to the functions shared with the system, the Smart-Vent controller both day and night free cooling and period


Laing O’Rourke, an international engineering enterprise EVO270 can fit into some of the smal ductwork. Additionally, becau many modern buildings now developments — and with the lo


use of its compact size, the need due to their exposed e lower acoustic levels that manding building


that has delivered some of the world’s most pr buildings, is responsible for t


the construction of the Brunel he world’s most prestigious ational engineering enterprise he smallest ceiling voids.


O’Rourke, says: “The building’s modern design inc James Brazier, mechanical Building in Paddington.


installed fan coil units which fitted the spac exposed high-specification servic exposed concrete features, al


active heating and cooling, as wel project had some very specific r Jon Freeman, product man and fulfilled our low noise output r to provide us with a product t well as the overall aesthetics


’s modern design incorporates l project manager, Laing


of the design. Ability was able fitted the space restrictions, as ervices. It was vital that we long with the installation of


that met our high standards


s well as noise restrictions. In fic requirements in terms of nager, Ability, says: “This tput requirements.”


The development has been designed to cr developers make substantial c duty in a smaller fan such as the EV Southampton. Also, by maint acoustic tests which are then guidelines and we put our FCUs thr towards quieter units. Buildings ha commercial buildings, we are


enjoying significant regenera office space and add to the vibr


Crossrail.


ngs have very clear acoustic e seeing an increased drive


n validated by the University of CUs through over 10,000


the EVO270, we can help aining heating and cooling


ation ahead of the opening of ibrancy of the area, which is n designed to create premium l cost savings.”


period, as selected by the building sing simple on/off enable switches.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44