also produce inaccurate results, because low boiling point compounds are lost during the evaporation stage. In addition, the method does not generate any information about the source of the contaminating residue, which is useful for troubleshooting purposes.


This study will therefore describe a new method using Automated Thermal Desorption (ATD) coupled with gas chromatography (GC), for the measurement of residue in LPG down to 5µg/g, as well as yielding the hydrocarbon range of the contaminants, to give an understanding about the source of contamination. This methodology has since become a new ASTM Method D7828, ‘Standard Test Method for Determination of Residue Composition in Liquefied Petroleum Gas (LPG) Using Automated Thermal Desorption/Gas Chromatography (ATD/ GC)’ [4].


Standard Test Method for Residues in Liquefied Petroleum Gases


ASTM D1835 states that besides the four main constituents of, methane, ethane, propane and butane, the residue contaminants, particularly longer chain hydrocarbons C6


-C40


electricity generation technology being designed for stationary energy applications, or fuel cells, which are used to convert hydrogen/hydrocarbon gases into electricity using proton exchange membrane (PEM) technology, a more sensitive test is required. It has been estimated that to use LPG for these kinds of applications, a residue detection capability of < 20 µg/g is required in order to ensure the efficiency and trouble- free operation of the technology.


Thermal Desorption Coupled with Gas Chromatography


To meet the detection requirements of these innovative new technologies, it was decided to investigate the use of Thermal Desorption (TD) coupled with Gas Chromatography (GC) and flame ionisation detection (FID). The objectives of the study were to:


• Achieve acceptable recoveries of hydrocarbons from C6


to C40


• Not retain compounds lighter than C6 to minimise interferences


• Ensure the pressurised LPG enters the tube as a liquid


, should be kept to an


absolute minimum, because they can lead to problematic deposits in liquid feed and vapour withdrawal systems utilised in end- use applications of LPG. These residues also have the potential to be carried over and can foul up regulating equipment, and over time, the ones that remain can accumulate, and could contaminate additional components.


ASTM Method D2158 involves taking a 100-mL sample of liquefied petroleum gas, which is evaporated at 38°C in a customised centrifuge tube, cooled with a condensing coil and cooling bath. The volume of residue remaining is weighed, measured and recorded. This test method has been used to verify heavy contaminants in propane and LPG products for many years. However, in addition to being time-consuming, labour- intensive, and often dangerous with harmful vapours escaping into the atmosphere, the test has precision limitations. Therefore, besides not being sensitive enough to protect some equipment from operational problems or increased maintenance, it also cannot identify the source of residue.


In fact, D2158 states that if the LPG is specifically being used for certain applications such as micro turbines, a new


• Achieve a detection capability of less <10µg/g and a dynamic range of 3 orders of magnitude


• Prove accuracy through an LPG quality control sample


• Attain acceptable repeatability


• Offer the potential of identifying the individual residue component or hydrocarbon profile for troubleshooting purposes


• Enable sampling in the field, so the sorbent tubes can be sent to a laboratory for analysis, saving significant transportation costs associated with shipping pressurised cylinders


• Reduce costs associated with cleaning (labour and solvents) and purchasing cylinders


• Make it rugged enough to be a standardised ASTM method


Thermal desorption is well-recognised as being an accurate and precise technique for the sampling and analysis of volatile and semi-volatile compounds by gas chromatography. It has become the industry standard for analysing soil gases, studying healthy building syndrome, fenceline monitoring, indoor/outdoor air analysis as well as addressing industrial hygiene concerns [5]. Sorbent tubes are small and light, making them easy to transport, and when applied to LPG samples at a remote site, it can result in reduced shipping costs compared to other sampling techniques. In addition, the tubes are easily cleaned during the desorption process, rendering them available for immediate re-sampling, which can be verified with a rapid GC analysis.


Summary of New Methodology


A sample of LPG is captured on a sample loop, which is maintained at a pressure above its bubble point as it is released directly onto the hydrocarbon selective absorbent tube material, thereby trapping the C6-


C40 hydrocarbon residue. After the


sorbent tube is sampled, it is brought or shipped to the laboratory for analysis by


Figure 2: Sample Tube Primary Desorption


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60