This page contains a Flash digital edition of a book.
»


SEPARATIONS AND PURIFICATIONS


»


Element Ni 231.604


Ni 232.003 Cu 324.752 Cu 327.393 Zn 206.200 Zn 213.857 Fe 238.204 Fe 239.562 Mg 285.213 Mg 279.077 Sn 235.485 Sn 283.998 Pd 340.458 Pd 363.470 Pt 265.945 Pt 214.423 Ru 240.272 Ru 349.894


Slope 47104


19274


341672 257957 69827 31714


108575 70306


350687 20116 8165.9 6987.5 71003 33962 10566 7254.6 53678 50825


Intercept 8540.5


2599.7 51031 32622 53859 9583.9 18642 10370


174239 2077.6 172.27 345.7


1111.2 3728.9 1333


1016.6 640.32 4754.4


Table 4. Linear Regression Covering 0.05 µg/mL to 50.0 µg/mL Correlation Coeffi cient R2


0.9970 0.9998 0.9996 0.9997 0.9938 0.9992 0.9997 0.9998 0.9969 0.9999 0.9999 0.9999 1.0000 0.9999 0.9998 0.9998 1.0000 0.9999


0.047 0.054 0.052 0.052 0.054 0.051 0.053 0.052 0.052 0.046 0.046 0.052 0.408 0.051 0.054 0.051 0.053


Element


Ni 231.604 Ni 232.003 Cu 324.752 Cu 327.393 Zn 206.200 Zn 213.857 Fe 238.204 Fe 239.562


LOQ (µg/mL) % Recovery


0.051 0.047 0.054 0.052 0.052 0.054 0.051 0.053


Mg 285.213 0.052 Mg 279.077 0.052 Sn 235.485 Sn 283.998 Pd 340.458 Pd 363.470* Pt 265.945 Pt 214.423 Ru 240.272 Ru 349.894


0.046 0.046 0.052 0.408 0.051 0.054 0.051 0.053


102 94


108 104 104 108 102 106 104 104 92 92


104 82


102 103 102 106


Table 5. Quantitation Limits and Detection Limits for Each Trace Element Wavelength LOD (µg/mL)


LOQ (µg/g) based on 20-mg/mL Sample Preparation**


2.55 2.35 2.70 2.60 2.60 2.70 2.55 2.65 2.60 2.60 2.30 2.30 2.60


20.40 2.55 2.70 2.55 2.65


0.002 0.003 0.003 0.001 0.001 0.001 0.001 0.001 0.001 0.001 0.007 0.010 0.001 0.023 0.004 0.005 0.001 0.002


* Percent recovery for Pd 363.470 was calculated using 0.50 ppm level standard due to lack of sensitivity of 0.05 ppm level standard. ** Limit of quantitation for each specifi ed metal is based on sample size used.


alternative detection wavelength in case spectral interference is observed at the primary detection wavelength. This also aids in minimizing potential false positives. Table 4 shows the results of the linearity


40 | | January/February 2015


studies. The correlation coeffi cients were >0.99 for all elements of interest. Based on the results, the method is linear over the concentration range of 0.05 ppm to 50.0 ppm for all elements assessed.


Quantitation Limits and Detection Limits


In APIs, the metallic impurities are usually present at residual levels pushing the


0.10 0.15 0.02 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.35 0.50 0.05 1.15 0.20 0.25 0.05 0.10


Quantitative Limit (LQ) N = 3 Standard Deviation 0.051


0.0009 0.0005 0.0017 0.0013 0.0007 0.0008 0.0009 0.0005 0.0016 0.0017 0.0014 0.0020 0.0007 0.0056 0.0021 0.0026 0.0005 0.0002


LOD (µg/g) based on 20-mg/mL Sample Preparation


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76