This page contains a Flash digital edition of a book.
[ Spotlight: Circuit protection ] Treat cable cleats as circuit protection devices, says Ellis


Leading cable cleat manufacturer Ellis has been extremely vocal in its attempts to draw greater attention to the importance of properly installed cable cleats in


electrical installations. ‘The problem we’ve faced trying to get our message across has been twofold,’ says managing director Richard Shaw. ‘Firstly, there are deeply ingrained installation short cuts that have happened so frequently and for so long that a lot of installers aren’t even aware they’re taking them. And secondly, because different cleat manufacturers don’t all work from the same hymn sheet the market is very much a mish-mash of products of differing quality.’


The publication of European (EN50368) and


international (IEC61914) standards has seen great strides taken in changing people’s attitudes towards cleats, but the journey is far from over,


thinks Shaw. ‘The standards are only advisory, which means those claiming adherence to them can do so through self-certification. And this is where the problems from the manufacturers’ end begin.’ It is common for manufacturers to claim a


given short circuit withstand at a given cleat spacing and legitimately provide third-party certification to support this. However, the overlooked fact is that the quoted short circuit withstand is only valid for a cable diameter equal or greater than the diameter of the cable used in the test. If the project in question is using smaller cables than those referred to in the test (and the fault level and spacing is the same), then the force between the cables is proportionally greater and the certificate is inappropriate. So, the question is how to resolve a potentially


fatal issue that is being inflamed by bad practice and misunderstanding from manufacturers, specifiers, contractors and installers. Of course, the situation could be resolved through a process of education and agreement involving all these


parties and industry regulators, but this would be a long-term process that fails to take into account the dire need for a quick-fix before the unnecessary threat to life caused by the problem turns into the wholly unnecessary loss of life. Therefore, there is only one sensible and


safe solution, according to Shaw. ‘Cable cleats need to start being treated as circuit protection devices – meaning they are given the same degree of importance as a fuse or a circuit breaker,’ he says. ‘After all, in the event of a fault, the forces between cables reach their peak in the first quarter cycle and this is the point that cleats earn their crust. In contrast, circuit breakers typically interrupt the fault after three or even five cycles, by which time, if the cleats are underspecified, the cables will be long gone. ‘The widespread adoption of this attitude


would ensure the correct use of and installation of cleats and when you consider what this means in terms of delivering safer electrical installation, it’s fair to say that such an approach is absolutely the right course of action.’ n www.ellispatents.co.uk


The ECA is more than a badge: it’s a valuable business benefit. For your customers, the ECA Guarantee of Work is an assurance that a completed job meets relevant standards. If not, the ECA will put it right*.


ECA Members also get:


• Technical advice on design, installation, inspection and maintenance


• Discounted training courses


• Reduced rates for BUPA cover, life insurance and pension scheme


• Commercial contracts and legal advice on a range of issues affecting your business


• Credit rating and debt recovery services


• Advice on employee relations, recruitment, disciplinary matters, employment law and industrial relations


David Lewis, Managing Director, Chancery Contracts Limited


• Health and Safety advice on how to reduce risks and comply with legislation


*Subject to conditions ECA. Here to help your business. eca.co.uk


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72