FEATURE u Test & Measurement


Yokogawa launches new Optical Spectrum Analysers covering wide wavelength range


The AQ6375E OSA T


o fulfil market demands for an instrument capable of measuring a wide range of wavelengths, to meet new needs in


optical product development and manufacturing, Yokogawa has launched two new optical spectrum analysers (OSAs) – the AQ6375E and AQ6376E. The new OSAs are offered in four versions.


The AQ6375E Standard has a wavelength range of 1200-2400nm; the AQ6375E Extended Wavelength version has a wavelength range of 1000-2500nm; the AQ6375E Limited version has a wavelength range of 1200-2400nm (with reduced wavelength resolution); and the AQ6376E Standard has a wavelength range of 1500-3400nm. The choice of wavelengths available gives


developers increased flexibility to apply the OSAs in a wide range of applications. These include environmental measurement and gas sensing, where the AQ637xE can be used in the measurement of gas absorption spectra and the characterization of light sources used in Laser Absorption Spectroscopy. Other major uses for the new OSAs are medical care and biotechnology and industrial laser applications. Typical applications will include the development and measurement of lasers; the characterization of broadband light sources such as supercontinuum light sources; optical passive devices; and optical fibres. The AQ637xE incorporates numerous features that contribute to achieving maximum accuracy. The free space optical input offers single-mode fiber for the SWIR and MWIR regions and MMF (up to 400 µm) on the same OSA. The small variation in insertion loss at the input connector increases measurement repeatability, while the


22 November 2022 Irish Manufacturing


The AQ6376E OSA


lack of physical contact with the connecting fibers ensures they avoid damage.


Also included is a built-in calibration light


source for optical alignment and wavelength calibration. This maintains high optical performance by compensating for deviations in the optical axis caused by vibrations and impacts and wavelength deviation caused by changes in ambient temperature. The AQ637xE also uses an air purging feature to compensate for another cause of possible error. In the SWIR and MWIR region, there are wavelengths where light shows strong absorptions due to the presence of water vapor and carbon dioxide, which can both disturb the spectral measurement. By continuously supplying pure purge gas such


as nitrogen to the monochromator through dedicated connectors on the back panel, the AQ637xE can reduce the influence of light absorptions on the measurement. High order diffracted light is also compensated


for through a built-in cut filter in all versions except the AQ6375E-01 limited model. This is required because the monochromator generates high order diffracted light, which has wavelengths equal to the integral multiples of the input wavelength. The built-in filters reduce this higher- order diffracted light, minimizing its influence on the accuracy of the measurement. To analyse results, the AQ637xE has built-in


analysis functions to characterize optical spectrum from a variety of optical systems and devices, such as WDM system, DFB-LD, EDFA, and filters. To improve measurement efficiency and


productivity, the AQ637xE features an application www.irish-manufacturing.com


(APP) mode, transforming a versatile OSA into a machine dedicated to a device under test (DUT). APP mode provides a DUT-specific user interface that allows the user to move from configuration settings to test results without the need to know the wide variety of OSA settings. The AQ637xE comes pre-installed with several basic applications such as WDM test, DFB-LD test, and FP-LD test. A guide through wizard leads the user through an easy set up process for specific measurements and analysis. New or additional testing applications will be


made available for download from the Yokogawa website and can be added to the AQ637xE by future firmware updates.


Enhanced user friendliness is achieved with


the unit’s high-resolution, responsive 10.4-inch multi-touch capacitive LCD touchscreen, which makes operating the device even simpler and more intuitive. The AQ637xE also features USB ports that are compatible with a USB storage device, mouse and keyboard. Data and screenshots can be saved to internal memory or USB storage to create test reports, while connecting a mouse or keyboard to the USB port allows the AQ637xE to be operated in the same way as a PC. The standard LAN port allows convenient access to files stored in the internal memory as well as allowing remote firmware updates from a PC. The APP function also supports a fiber inspection probe, allowing users to visualize the quality of the fiber connector surface.


Yokogawa www.yokogawa.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40