www.heatingandventilating.net


Decarbonising commercial hot water without the bespoke price tag


For commercial buildings the mandate to decarbonise is clear. However, the path to Net Zero is often obstructed by aging infrastructure, limited plant room space, and the high capital expenditure associated with bespoke engineering


I


n commercial settings, Domestic Hot Water (DHW) can account for up to 30% of a building’s daily energy consumption. While transitioning to


electrical alternatives is a pillar of sustainability, high-temperature water heating remains a challenge. To meet peak demands and strict anti- legionella regimes, owner/operators often feel trapped between costly, oversized heat pump installations or high-operating-cost direct electric systems, so it is falling to consultants and contractors to offer up alternatives. Adveco’s FUSION TW/TWplus


reimagines this transition. It offers a packaged, pre- sized hybrid approach that slashes emissions while bypassing the complexities of bespoke design.


Redefining the Hybrid Approach


FUSION serves as an alternative for new builds and gas-to-electric retrofits. Rather than relying on a single large, expensive heat source, it harnesses a hybrid architecture. By offsetting primary heating with a low-carbon alternative, it reduces grid demand, driving savings superior to both gas and standard direct electric systems. At the heart of the FUSION TW/TWplus is the


integration of an ADV-W series air source heat pump (ASHP) and the ARDENT electric boiler. These units work in tandem with a 750-litre ATST twin-coil cylinder to create a highly efficient indirect water heater. The TWplus incorporates an additional backup immersion for assured operation with no single point of failure. A common pitfall in commercial HVAC is the


drop-off in efficiency when heat pumps are forced to work at high temperatures. To reach required flow temperatures (+55°C), heat pumps need to work harder, drawing more energy and increasing costs. Adveco, in partnership with Midea, developed the ADV-W range to solve this. These monobloc units maintain high seasonal efficiency while delivering a continuous 60°C output. This ensures a consistent pre-heat, allowing the top-up heating to easily reach the +65°C required for legionella protection. Furthermore, the use of R32 refrigerant reflects


a commitment to safety and the environment. R32’s lower Global Warming Potential (GWP) enabled a compact, single monobloc outdoor form factor which is lower cost to purchase, install and operate. Supporting the ASHP is the ARDENT electric boiler. Unlike traditional immersion systems prone to


28 September 2026


limescale, the ARDENT operates in a sealed ‘primary loop’ configuration. By recirculating a finite amount of water through a heat exchanger, it eliminates scale issues, extending the unit’s lifespan and reducing maintenance callouts. New enhancements, including a larger primary heating coil within the cylinder means even greater power, up to 24 kW, is now available from ARDENT in the same compact 400 and 580 litre form factors. In such an iteration it is possible to meet instantaneous draw off demands of up to 225 litres or maintain continuous flow rates of up to 855 litres/hour for the most demanding applications. The greatest risk in a hybrid system is


‘contention,’ where two sources work against each other. FUSION excels through smart control which deploy intelligent climate curves, adjusting water temperatures based on external conditions (-20°C to +43°C). The system maximises the heat pump’s


contribution—potentially covering 70% of total heat requirements—before blending in the ARDENT boiler. For the FM, the system ‘thinks’ for itself, managing stepped power control to reduce start-up current. With an included GSM module, fault notifications are sent via BMS or text, allowing for remote management.


Tangible Savings and Proven Success


FUSION’s adoption is driven by verified data. Compared to direct electric DHW systems, FUSION delivers an average carbon saving of 36.3%. The figures are even more striking when moving away


from gas, delivering an average of 60.8% carbon savings, with some variants reaching 67.86%. For organisations with specific renewable goals, the base TW cylinder variant can be supplied ready to integrate solar thermal rather than ASHP pre-heat. Adveco’s controls ‘cheat’ the system in favour of solar input, providing an ultra-low-carbon application with a minimal rooftop footprint. Perhaps the most compelling argument is


the cost-to-performance ratio. Traditional high- temperature heat pump specifications can be prohibitively expensive; Adveco has demonstrated that a centralised FUSION system can match these specs for a tenth of the cost. By offering 25 pre- sized TW variants, FUSION removes the need for bespoke engineering, providing an off-the-shelf, ready-to-go system that reduces installation downtime.


Named Commercial HVAC Product of the Year


by Heating at the 2025 Energy Saving Awards, and receiving further accolade at the 2026 National Heat Pump Awards, FUSION has already been embraced by commercial and public sector organisations throughout the UK The release of the TW and TWplus variants sees FUSION fast becoming the standard for organisations across hospitality, retail, healthcare, education and the public sector. What unifies all these organisations is the refusal to choose between sustainability targets and operational budgets. For consultants and contractors FUSION TW/TWplus is a scalable, reliable resolution to the most pressing challenge in modern building services.


https://adveco.co/


DOWNLOAD THE HVR APP NOW


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32