search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
COMMERCIAL SUPPLEMENT


BOILER Ideal Heating – Commercial Products


Address: National Avenue, Hull, HU5 4JN Contact: 01482 498376, commercial@idealheating.com Web: www.idealcommercialheating.com


Product name - fuel type - boiler type - wall or floor-standing - output range - maxium gross efficiency - NOx emissions - size • Evomax 2 - Natural Gas, LPG - Condensing - Wall- hung - 30kW – 150kW Natural Gas (7 models), 30kW – 120kW LPG (6 models) Cascade kits up to 900kW - 96.2% - 97.2% Seasonal Efficiency - 33.9mg/kWh – 35.2mg/kWh NOx emissions (Natural Gas), 41.6mg/ kWh – 67.7mg/kWh (LPG) – 500mm x 850mm x 360-610mm • Imax Xtra 2 - Natural Gas - Condensing - Floor- standing - 80kW – 280kW (6 models) - Cascade kits up to 1120kW – 95.7% Seasonal Efficiency – 26mg/kWh – 35mg/kWh NOx emissions – 600mm x 1150mm x 796mm-1048mm • Imax Xtra EL - Natural Gas, Condensing - Floor- standing - 320kW – 1240kW (10 models) - 96.8% - 97.0% Seasonal Efficiency - 35.8mg/kWh – 39.1mg/ kWh NOx - 835-1674mm x 1485mm x 1685mm • Evomod - Natural Gas, Condensing - Floor- standing - 250kW – 1000kW (4 models) - 95.9% Seasonal Efficiency - 39.7mg/kWh NOx emissions - 710-1428mm x 860-2100mm x 1339mm • Evojet - Natural Gas, LPG, Oil, Dual Fuel - Condensing Pressure Jet - Floor-Standing - 150kW


– 3000kW (14 models) - 95.7% - 96.5% Seasonal Efficiency - NOx emissions depend on burner installed - 740-2000mm x 1315-2180mm x 1455- 4615mm


Installation aids available • Skid-mounting kits • Flue kits • Frame & header kits • Hydraulic separation • Insulation kits • Pumps


Controls available • Weather compensation • Cascade control • Sequencers • Integrating controls


Other products available • Air source heat pumps • Heat interface units


Brief company history • Country of origin: UK


• Founded in: 1906 • Established in the UK in: 1906 • Number of employees in the UK: 1048


• Built by us trusted by you: Ideal Heating have been designing and manufacturing boilers at our site in Hull since 1906, we are one of the few true British manufacturers left in the heating industry. We have developed a range of hand-made commercial boilers with the distinctive features needed for UK installations. Our manufacturing process incorporates best practices learnt from large-scale UK production, ensuring high and consistent standards of reliability and efficiency. • Free Commissioning: All our boilers are eligible for free commissioning by one of Ideal Heating’s experienced service engineers. This continues to be the most comprehensive and consistent commissioning package available. • The UK’s number one - Evomax 2: our market- leading wall-mounted commercial boiler is now available with a 10-year warranty. • Market-leading warranties: Imax Xtra 2, Imax Xtra EL and Evomod floor standing boilers have a 5-year Heat Exchanger warranty, when commissioned by Ideal Heating.


Unique selling points


CaseStudy T


hree Evomax 2 commercial condensing boilers from Ideal Commercial Heating have been installed at the 208-bedroom Littlecote House Hotel in Berkshire. A Grade I listed Tudor manor house, Littlecote House is one of England’s most historic country house hotels. When the heating system serving the original manor house reached the end of its service life, mechanical engineering specialist J&B Hopkins selected three Evomax 2 120kW wall-mounted commercial condensing boilers operating in cascade, delivering a total output of 360kW to serve the historic section of the hotel. The boilers were installed on an Ideal Commercial Heating low-height frame and header kit, complete with preformed insulation kits. The project presented several challenges due to the age and status of the building. Much of the


existing heating system is around 100 years old and, because of the Grade I listing, there was a requirement to retain as much of the original infrastructure as possible. To achieve this, a low loss header was incorporated into the design, providing hydraulic separation between the new boiler cascade and the existing heating system. This enables both systems to operate independently, ensuring stable flow rates through the boilers. Located within a 500-year-old cellar and accessed via an uneven staircase, the installation required equipment that could be transported safely without risking damage to the historic structure. The compact dimensions and lightweight aluminium heat exchangers of the Evomax 2 boilers made them particularly well suited to the application. Rather than attempting to install a single large boiler, the cascade arrangement allowed three smaller units to be manoeuvred into position while still providing the required output. The installation was supported by Ideal Commercial Heating’s free commissioning service, which also activates a five-year warranty on the boilers at no additional cost. idealcommercialboilers.com


DOWNLOAD THE HVR APP NOW


September 2026 23


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32