VENTILATION & HEAT RECOVERY
Healthcare ventilation design and integrated heat pump technology
Healthcare ventilation design involves far more than achieving a specified airflow or room temperature. Hospital air handling units (AHU) must support infection control, maintain stable environmental conditions and provide safe access for cleaning and maintenance. Healthcare providers must also reduce energy consumption, carbon emissions and dependence on fossil-fuel heating
T
hese requirements have driven Damvent’s development of the max.e2 DH: a packaged healthcare AHU solution combining heat
recovery, reversible heat-pump technology and integrated controls.
The challenge of healthcare ventilation
Traditional healthcare systems commonly use separate AHUs, boilers, chillers, pumps and control panels. Although familiar, this approach creates interfaces between equipment manufacturers, controls specialists and installers. It can also require considerable plant space, particularly difficult in refurbishment projects and constrained hospital sites. Heating and cooling outdoor air is energy intensive.
Healthcare systems frequently operate for extended hours and, in critical areas, continuously. Equipment must therefore perform efficiently across its entire operating range, not simply at one design condition. Damvent’s objective was to develop a more
integrated solution without compromising the hygiene, maintainability and resilience expected of healthcare ventilation equipment. Damvent began the focused development of an HTM 03-01 healthcare solution in 2022. This followed earlier experience supplying UK healthcare projects and a detailed assessment of how the established max.e2 integrated heat-pump platform needed to evolve. The development process included input from UK
healthcare ventilation specialists and Authorising Engineer (Ventilation) expertise. This helped translate HTM 03-01 principles into practical manufacturing, filtration, access, drainage, controls and maintenance requirements. The first units resulting from this programme
were delivered to the UK market in late 2023. Further projects and technical reviews have continued to inform the product, making development an ongoing process rather than a one-time compliance exercise. The “DH” designation distinguishes this
22 November 2026
P22_HVR_NOV26.indd 22
healthcare configuration from Damvent’s standard commercial max.e2 platform.
Three-stage energy recovery
At the centre of the solution is a three-stage approach to energy recovery. The first stage uses passive heat recovery to
transfer energy between the extract and incoming outdoor air streams. Depending on project requirements, the selected technology can also assist with humidity recovery. The second stage is active thermodynamic
recovery. A reversible heat-pump circuit extracts usable energy from the exhaust air and transfers it to the supply air during winter. In summer, the cycle reverses to provide cooling. A third stage can provide additional conditioning, including dehumidification and controlled reheat where required. This is particularly valuable in clinical
www.heatingandventilating.net
areas where temperature control alone is insufficient. Combining passive and active recovery can produce
a high overall system coefficient of performance. This system COP reflects the benefit of the complete energy- recovery process, not merely compressor efficiency.
A packaged solution
The refrigeration circuit, compressors, coils, controls and safety functions are assembled and tested as part of the AHU. This reduces site- installed refrigerant pipework and removes many interfaces associated with separate condensers, chillers or air-to-water heat pumps. Each unit can operate as a decentralised heating and cooling source for its designated area, reducing distribution losses, pumping energy and dependence on central heating and chilled- water networks. Damvent develops and tests the refrigeration, airflow and control sequences as one coordinated system.
Designed around healthcare requirements
The solution incorporates hygienic internal finishes, appropriate filtration, accessible components, inspection facilities and stainless-steel drain pans with a positive fall for effective condensate removal. Compressors and associated valves are located out of the air stream and housed in accessible compartments within the extract-air section, separating them from the clean supply-air path. Refrigerant selection, leak detection and control responses are assessed as part of the project safety strategy. Coil design balances heat-transfer performance,
air resistance, cleanability and frost protection. Damvent has therefore considered fin spacing, protective coatings, condensate management and inspection access. Winter performance is especially important.
Integrated heat pumps serving 100% outdoor air must operate under realistic low-temperature and high-humidity conditions. Appropriate coil circuiting and control strategies limit frost formation and prevent reliance on conventional defrost cycles.
The future of healthcare air handling
Healthcare estates need ventilation solutions that support infection control while responding to decarbonisation, energy-cost and space pressures. Integrated heat-pump AHUs can simplify the overall system and recover energy that would otherwise be discharged from the building. Damvent’s solution represents its progression
from an established commercial hybrid AHU platform to a healthcare-focused solution developed through project experience, specialist consultation and continuous technical review. Its significance lies in bringing ventilation, heat
recovery, heating, cooling, dehumidification and controls together as one coordinated system — designed around the demanding realities of modern healthcare ventilation.
DOWNLOAD THE HVR APP NOW 30/10/2026 10:02
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44