Supplement: Power
system protection. The auxiliary contact mechanism shown in figure 1 ensures safe insulation, with a withstand voltage of 2.5kV or minimum contact gap of 0.5mm, even after the coil is de-excited when the main contacts have a welding failure.
Among the inherent advantages of relays, smaller component dimensions permit more compact and lower-profile enclosure sizes. This can be important for consumer markets that desire fashionable and minimalist styles to industrial and utility applications challenged to install more and smarter infrastructure within existing space constraints. Contrasting the properties of a typical contactor with a comparable relay reveals more than 66 per cent weight saving, as well as more than 60 per cent less height and 85 per cent lower volume. The relays’ smaller size and typically lower weight permit PCB mounting of high-power switches that can simplify and streamline equipment assembly. PCB- mounted components are compatible with automated production processes, allowing circuits to be assembled at high speed using inline insertion equipment. Subsequent automated soldering lets equipment vendors design-out traditional bulky and expensive components such as busbars and screw terminals that need to be manually
www.cieonline.co.uk
fastened. In addition to permitting faster and more efficient assembly, soldered connections save human errors such as incomplete screw tightening or applying incorrect torque, permitting more consistent production quality.
On-boarding
Moving established design practices and production flows away from traditional manually installed contactors to PCB-mount relay assemblies involves literally going back to the drawing package to create a new circuit-board design. PCB design guidelines include ensuring adequate copper thickness to carry the intended current, noting that enlarging the terminal surface area can help boost heat dissipation. A heatsink or insulated metal substrate can help protect the board in applications that demand extremely high current. In addition, for high-capacity PCB relays, implementing a holding-voltage circuit or PWM drive circuit to minimise power consumption can effectively ease thermal management and can potentially reduce the drive power to 25 per cent. Equipment vendors can recoup the investment to redesign their PCBs through greater saleability, delivering smaller, lightweight PCB-based assemblies that fulfil market desires.
The production area may also need to be reorganised to reduce or remove manual workstations and migrate production onto automated machinery for through-hole assembly. A comparison of production techniques suggests that soldered terminals can reduce the bill of materials (BOM) including busbars and screws by up to 35 per cent, while assembly-process costs can be reduced by as much as 50 per cent. The benefits gained through automated assembly become more significant as production is scaled to larger volumes.
In addition, changing to PCB relays can enhance product performance and improve energy efficiency. The lower contact resistance of these relays leads to reduced I2R losses and heating thereby extending contact reliability. In addition, the coil power is lower, contributing further to increased efficiency.
OMRON’s high-current PCB relays include the single-pole G9KA-1A1B-E, which can carry up to 300A and has main contact resistance less than 0.2mΩ. The design of the mechanism and the materials selected contribute to the low resistance and also permit a contact gap of 4.0 mm ensuring high performance with safety. There is also a 30V/1A mirror contact
structure built-in to provide weld detection meeting IEC 60947-4-1, the international standard for electromechanical contactors and starters including motor protective switching devices.
Overall, while moving to PCB-mounted solutions requires upfront investment, vendors gain significant long-term payback in cost, efficiency, and reliability.
Conclusion
Electromechanical contactors are historically accepted as the kings of high-current switching, covering a wide range of ratings up to hundreds of Amps. While their strengths also include auxiliary fault- detection contacts, there are disadvantages. Devices tend to have a large and heavy coil and contact mechanism, which adds bulk and limits switching frequency, while manual assembly methods slow production and allow scope for human error. New demands arising from electrification are driving innovations in PCB relays that elevate current-handling capability and provide built-in fault detection, presenting a new option in the 50-300A range that permit more compact, reliable, efficient, and cost-effective power control.
https://components.omron.com/eu-en/ Components in Electronics December/January 2026 39
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52