Protecting the backbone of clean energy


By Mike Torbitt, managing director of resistor manufacturer Cressall I


n the UK, the share of electricity generation from renewable sources during the second quarter of 2025 reached a new record level of 54.5 per cent of all generation, according to the Department for Energy Security and Net Zero. But as we shift closer to a net-zero energy system, it becomes critical to have a robust storage solution to harness the energy we produce.


The Government’s Clean Power 2030 Action Plan, introduced in December 2024, looks to ensure that clean sources produce “at least as much power as Great Britain consumes in total” and “at least 95 per cent of Great Britain’s generation”. Achieving this will rely on a blend of offshore wind and solar energy deployed at scale.


But this transformation hinges on flexibility. As wind and solar dominate, BESS (Battery Energy Storage Systems) is becoming the backbone of grid stability, absorbing excess renewable energy and releasing it during demand peaks. Lithium-ion technology leads the way here, comprising 95 per cent of UK BESS projects, thanks to its rapid response and scalability.


The BESS landscape


Higher renewable penetration has driven demand for energy storage. As of September 2025, RenewableUK reports 1,943 active battery storage projects in the UK, with 6.8 gigawatts (GW) of operational capacity — a 509 per cent increase since 2020. Even larger projects are underway. Tillbridge Solar in Lincolnshire will deliver 1.5 GW of solar PV and three GWh of BESS, while Pembroke Battery in Wales will become the UK’s largest storage facility when construction begins in early 2026. These assets will provide fast frequency response, peak shaving and renewable firming. Their success, however, depends on safe, reliable integration into medium- voltage (MV) grids. Systems typically connect at 6–36 kV, where grid code compliance, fault studies and earthing design are critical. Without robust protection, the promise of storage could falter under grid physics.


MV challenges MV grids are faultenergy rich environments. 10


In solidly earthed MV systems, a single line- to-ground fault can drive very high currents, imposing severe thermal and mechanical stress on stepup transformers, converter valves and switchgear.


For BESS, rapid dispatch and high- power flows amplify risks such as inrush currents, transient overvoltages and earth faults escalating in milliseconds, posing compliance and protection challenges under the GB Grid Code. Without controlled earthing, fault magnitudes can exceed clearing times and equipment limits, risking outages and costly repairs.


As grids add high voltage direct current (HVDC) links to ferry offshore wind and remote solar, and as BESS ties into converter stations or MV collectors, abnormal conditions like DC faults reflected into AC neutrals demand predictable neutral behaviour. Limiting ground fault current is essential to maintain converter transformer integrity and prevent cascading trips.


Making BESS safe


This is where neutral earthing resistors (NERs) do the quiet, but crucial work. By inserting a defined resistance between the transformer neutral and earth, an NER limits earth fault current to a level that protection relays can detect and clear selectively, without tripping the entire plant.


NERs prevent transformer insulation FEBRUARY 2026 | ELECTRONICS FOR ENGINEERS


damage, reduce arc flash hazards, minimise voltage stress on equipment, enable controlled fault detection and isolation and maintain system stability during fault conditions. Cressall supplies NERs tailored for MV and HV duty in renewables and storage, with engineering guidance that highlights how DC and AC NERs protect converter transformers and maintain system integrity during abnormal events — requirements that map directly to MVconnected BESS. Every Cressall NER is designed to IEC and IEEE standards, factory tested under fault current conditions and built with stainless steel elements for outdoor durability. They are rated for continuous operation in harsh environments, ensuring reliability in demanding renewable installations. In practice, this means fewer catastrophic stresses on transformer windings and converter components, better adherence to grid code protection settings and smoother interconnection approvals.


The UK is reshaping its energy system, but success depends on more than megawatt- hours. Behind every project sis a layer of protection technology that keeps the grid stable. As the UK races toward Clean Power 2030, NERs are foundational, turning unpredictable faults into manageable events, making MV-connected BESS bankable and resilient.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50