BSEE FIRE & SAFETY
Martyn Walley, National Technical Manager at Aico Ltd, looks at the benefits of interconnecting domestic smoke alarms with third party safety systems and how best to achieve this.
Advertising: 01622 699116 Editorial: 01354 461430
SMOKE ALARM SYSTEMS Making the right connections
‘ Smoke alarms
have developed considerably over the years, from improved response times through to greater system flexibility. This latter aspect in particular has had a
considerable impact for homeowners, landlords (especially in social housing) and installers alike.
’
system (there were none to add in any case), you couldn’t integrate them with other alarm systems, and you certainly couldn’t interconnect to third party equipment. To do that required a commercial Part 1 system, which is entirely unsuited to the vast majority of residential properties, not to mention expensive. Smoke alarms have, of course, developed considerably over the years, from improved response times through to greater system flexibility. This latter aspect in particular has had a considerable impact for homeowners, landlords (especially in social housing) and installers alike. Now, there is a raft of valuable system add-ons, such as alarm control switches, and the ability to connect smoke alarms to other systems. This has led to domestic smoke alarms encroaching more into the commercial sector, such as care homes and assisted living schemes. In what circumstances would you want to connect a domestic fire alarm system to what is essentially a commercial one? The answer: when that Part 1 panel based fire alarm system is fitted in the communal areas of Houses in Multiple Occupation (HMOs) and apartment blocks. In this instance the individual apartments would be fitted with a BS5839 Part 6 domestic smoke alarm system; if this is triggered it will only sound within that individual flat. To maximise safety and ensure the communal alarm can be heard within each property, it is beneficial to integrate the two alarm systems so that the Part 1 communal system will activate all alarms throughout the entire building if a fire is detected, but does not allow individual flats’ alarms to activate those in the communal areas or other within other tenant’s homes.
D call systems
uConnecting to the fire panel or warden call system.
Telecare/warden call systems are commonplace in dwellings for vulnerable people and are an important tool to let people live independently in a safe environment, but in most situations they are not connected with the smoke and CO alarms in the property. If a fire was to start or there was a CO leak, the alarms
Warden
omestic smoke alarm systems used to be pretty much self- contained affairs – you couldn’t add accessories to a
would activate but external assistance would not be sought; this could be fatal. The ability to integrate these different systems means that if an alarm goes off an emergency signal can be transmitted directly to the warden call system and on to the alarm receiving centre, if used. Assistance to evacuate the property, if necessary, can then be provided quickly for maximum safety and peace of mind.
Sprinkler systems
Sprinkler systems are becoming more commonplace in domestic properties; in Wales they are a legal requirement in all new build homes. Connecting the smoke alarm system to the sprinkler system is an obvious choice. If the sprinklers activate, an alarm can be triggered throughout the property providing occupants with plenty of time to evacuate.
Pain free system connection
Not all smoke alarms are capable of connecting seamlessly with third party systems; in fact, remarkably few can genuinely claim to do so. Most will only be able to achieve this through the use of relays, which will work but, as they haven’t been specifically designed for this purpose, limit what you can do and how you do it.
Instead of utilising existing product and adapting it to work adequately, Aico has approached the challenge by researching what customers really want to achieve from integrating alarms with third party systems and developed a specific solution that accommodates those needs. This has led to the introduction of our Ei414 Fire/CO Alarm Interface, which provides a dedicated connection between Aico smoke and CO alarms and third party safety systems. The connection to the other system can be made wirelessly with Radio Frequency (RF) or via hard wiring directly between the two devices. The Ei414 Fire/CO Alarm Interface itself features Aico’s award winning RadioLINK RF technology. It can be powered directly from the mains or from a 12-24V DC supply and has built- in tamper-proof rechargeable Lithium Cells which will power the device in the event of any mains failure.
Systems connection in practice
The Ei414 Fire/CO Alarm Interface Interface has already been successfully used in many applications and is proving particularly useful in the social housing sector.
Fife Council, for example, is undergoing a programme to install 30,000 Ei414 Fire/CO Alarm Interfaces throughout its housing stock. Previously it had been using different components which did not ‘talk’ to each other, resulting in a potential safety issue. The Ei414 Fire/CO Alarm Interface overcomes this, directly interacting with the different systems
20 BUILDING SERVICES & ENVIRONMENTAL ENGINEER AUGUST 2017
fitted within the properties to ensure the safety of the council’s tenants. The council initially intended to use the interface in sheltered housing properties, connected to warden call systems. The Ei414 Fire/CO Alarm Interface not only triggers the Telecare/warden call system in the event of an alarm activation, but has added benefits in that it can also signal to the warden call system if any alarms are removed from their base, have a low battery, etc. Fife found the Ei414 Fire/CO Alarm Interface so flexible and easy to use, that it has since made the decision to extend its use to its entire housing stock. The RHP Group, a registered housing provider in South West London, is also using the Ei414 Fire/CO Alarm Interface, but to meet a very specific safety requirement in HMOs. Each flat within the HMO already benefits from an Aico BS5839 Part 6 domestic smoke alarm system – if this is triggered it will only sound within that flat. Throughout the common circulation areas a separate communal BS5839 Part 1 fire alarm system has been installed.
Communal alarm
To maximise safety and ensure the communal alarm can be heard within each property, RHP has integrated the two alarm systems. This has been achieved by installing an Aico Ei164e Heat Alarm in the hallway of each flat, which interconnects to the existing alarm system within the flat. These Ei164e Heat Alarms are also interconnected to an Aico Ei414 Fire/CO Alarm Interface, which in turn is connected to the communal alarm system in the common parts. Interconnecting domestic smoke alarm systems with other safety systems remains a relatively new development but one that is rapidly taking traction. The social housing sector, in particular, has been quick to see the benefits and make the most of this relatively low cost added safety measure. Private housebuilders and developers are also showing an interest, especially for interconnecting to sprinkler systems, as are care homes where safety is paramount. For those involved in recommending such systems, ensuring the use of good quality alarms that provide such flexible solutions provides a genuine opportunity to add value to your business.
uConnecting the smoke alarm system to a domestic sprinkler system is becoming more commonplace.
‘
Interconnecting domestic smoke alarm systems with other safety systems remains a relatively new development but one that is rapidly taking traction. The social housing sector, in particular, has been quick to see the benefits and make the most of this relatively low cost added safety measure.
’
www.aico.co.uk VISIT OUR WEBSITE:
www.bsee.co.uk
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40