Connectors & cables
Stopping sparks flying
The design considerations of hot-disconnect connectors
Imagine needing to go to the breaker box to turn off your entire home’s electricity supply every time you want to plug or unplug something. Now take that inconvenience and scale it up a thousand times. Imagine a factory needing to disconnect equipment thousands of times a day, possibly in explosive or hazardous atmospheres, and the problem becomes clear. Here Nick Lewis, PEI-Genesis, discusses hot disconnecting in industry.
arguments it is difficult to disagree. British plugs include fuses, a built-in ground terminal and yank protection, which are found almost nowhere else in the world. One particularly innovative part of the design is
T
that the ground terminal is five millimetres longer than the live and neutral terminals. The ground makes contact first, which provides an escape route for any excess charge as the live and neutral
he UK has the best plugs in the world, at least as far as YouTuber Tom Scott is concerned. Once you go through the
contacts mate a moment later. The practical upshot of this is that British plugs are far less likely to arc when connected or disconnected. Connecting and disconnecting powered
connections like this is known as hot disconnecting in industry and, while avoiding arcing is beneficial for safety in the home, in industry the risks are far higher.
ONLy dIscONNEct The first question is — why hot disconnect at all? If equipment is powered down before disconnecting, all the associated problems can be avoided. For small industrial applications this is acceptable, but as factories expand this solution becomes impractical. Powering down equipment can lead to major losses in production and can be a very time consuming and labour-intensive process to plan and implement. Many industries work this way, and the only
real consequence is a reduction in the connector’s cycle lifetimes as the arcs slam into the contacts over and over. This arcing can lower cycle ratings by over 500 times, so it is certainly a factor to keep in mind, but the increased cost of replacing connectors 500 times more frequently are massively
18
outweighed by the increased production generated by keeping equipment powered up. Another contributing factor is that industrial
voltages are often many times larger than the 230 volts of home circuits. The possibility of arcing is a direct function of the voltage and the distance between the contacts, so a larger voltage makes for stronger and longer arcs. Because the contacts start off touching,
some arcing is unavoidable at the point they un-mate. This is limited in connectors which include a longer grounding terminal, just like the standard British plug, but arcing will always occur to some degree.
ONLy cONNEct However, there are some industrial situations where even minor arcing poses danger, most notably explosive environments. The threat of catastrophic explosive
consequences for arcing in these environments means that ATEX certified hot-disconnect connectors require an additional design consideration. These connectors, like the Trolex Falcon25, use a two-stage connecting process. First the enclosure mates, and then the live contacts. This creates an explosion-containing
February 2021 Instrumentation Monthly
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74