American P&I Club releases an animated video on how condensation forms as a result of ship sweat


As part of their series, the American P&I Club has published a helpful short animated video running to 7 minutes which give an overview and summary of how condensation forms as a result of ship and cargo sweat.


Moisture damage is the source of a significant number of cargo claims, often involving bagged or bulk agricultural products. Claimants typically allege that failure by the ship to ventilate correctly resulted in the development of condensation (commonly known as “sweat”), causing the cargo to deteriorate.


In addition, the formation of rust on cargo is greatly accelerated when relative humidity is greater that 60%. Best practice is to keep relative humidity below 40%. However, it is important to recognise that some commodities may have inherent moisture levels which exceed acceptable limits at the time of loading, making them biologically unstable. Such details may not be known to the ship, and prudent ventilation measures may be insufficient to prevent the cargo from deteriorating on passage.


Recommended rules for ventilating steel cargoes


The 3 degree Celsius rule: Ventilate when the dew-point of the outside air is least 3 degrees C below the temperature of the cargo taken during loading. New point rule: Ventilate when the dew-point of the outside air is lower that the dew-point of the air in the hold.


According to the American P&I Club, all readings must be recorded in the ships cargo record book. Furthermore, both wet and dry bulb readings must be obtained at each position and the dew point temperatures carefully determined. The effectiveness of dehumidification is dependent upon the provision of a constant airflow throughout the hold.


Watch the video at https://bit.ly/3RdbxgP.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37