EMENT s for dealing with damp.


When using a hygrometer, it’s important to allow sufficient time to allow entrapped air to reach moisture equilibrium with the screed or base before the unit is switched on. Equilibrium can be assumed either when consecutive readings, taken at four hourly intervals, show no change, or if the instrument is left in position overnight.


NEXT STEPS There are a number of options available to contractors for creating a barrier between floorcovering and subfloor where excess levels of subfloor moisture are detected.


The application of a waterproof surface membrane is the usual solution for effectively controlling damp. Advanced products are now available, such as F. Ball and Co. Ltd.’s Stopgap F77, that will isolate excess subfloor moisture where relative humidity values are up to 98%, with a single coat application, which will fully cure in as little as three hours.


F. Ball’s Stopgap F78 provides an even quicker, two-coat system. The first coat cures in 15-20 minutes. A second coat cures in 30 minutes to create an effective barrier against residual construction moisture where relative humidity values are up to 95%.


ALTERNATIVE SOLUTIONS An alternative solution for dealing with damp is available where a waterproof surface membrane cannot be applied. This may be the case where screeds are contaminated with oil, other chemicals or old adhesive residues, as well as in historical settings where the subfloor must be preserved.


the subfloor is dry enough to proceed with the installation of new floorcoverings. A quick, non-intrusive way to identify the presence of subfloor moisture is to use a handheld radio frequency moisture meter. If the device indicates the presence of moisture in the subfloor, further testing will be required to determine subfloor relative humidity levels and the requirement for a moisture management solution.


The only method of measuring subfloor relative humidity levels with certainty, and the method advocated by British Standards, is to use a calibrated hygrometer. Affixed to the subfloor using butyl tape to create an airtight seal around the base of the instrument, these devices measure the relative humidity of a small volume of confined air in equilibrium with the subfloor, taking into account the ambient temperature.


twitter.com/TContractFloors


In these situations, a loose-lay isolator membrane, such as F. Ball’s Stopgap Isolator Membrane, can be laid directly onto the subfloor, without the requirement for an adhesive, to provide a barrier to stop excess subfloor moisture causing floor failure.


The membrane has nodules on the underside, creating an airspace to allow water vapour to travel to the edge of a room, into a dry wall or ventilated area, where it can safely escape. A wide range of floorcoverings can be adhered to its upper surface.


By acting as a base to receive resilient floorcoverings and carpet tiles, loose-lay isolator membranes allow durable new floors to be installed and easily removed at a later date, allowing buildings to be returned to their original state, offering a solution for temporary flooring installations.


www.f-ball.com SUBFLOOR PREPARATION | 31


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44