MATERIALS HANDLING


particularly resilient and robust. A common problem is that the shaft seal and cable inlet are attacked and destroyed by the fluids. Tis causes the medium to enter the motor housing, which – at worst – can lead to a total failure of the pump. In addition, the non-resistant metallic components corrode through contact with the aggressive media, which reduces the performance of the pump and can also cause a defect. German firm Homa Pumpenfabrik has


W


therefore developed a comprehensive range of stainless steel submersible pumps. Te individual series CH, CTP, CMX, CV, CVX and CK are equipped with discharge connectors from 2in to DN 150. Te CH430 series is characterised by a compact and robust design, which allows flexible use in the chemical industry and the transport of bilge water in shipping. Te units are made of resistant,


investment cast stainless steel, which means vibrations are absorbed more effectively, with less resultant stress on the bearing and mechanical seal. Tis increases the service life and considerably reduces maintenance intervals. “To reliably and safely convey chemical fluids and waste water contaminated with chemicals, the pumps used must be particularly resilient,” explains Stephan Wild, responsible for technical project planning at Homa Pumpenfabrik. “If the shaft seal or cable inlet is decomposed by the medium, the aggressive chemical fluid gets into the motor compartment, ultimately causing the pump to fail.” Moreover, non-resistant metallic components may corrode due to contact with the medium being handled, resulting in reduced functionality or a pump defect. Te stainless steel submersible pumps from Homa are suitable for continuous operation in the chemical industry and for the disposal of chemically contaminated waste water. “Te highly resistant investment cast stainless steel used makes the series resilient against aggressive fluids,” Wild adds. “In addition, contaminated water containing solids such as sand and sludge can also be pumped. With the


38 www.engineerlive.com


hen pumping chemically aggressive and abrasive wastewater, as well as liquid chemicals, pumps must be


Stainless steel submersible pumps


Corrosion causes damage to non-resistant metallic components: a pump series made of investment cast stainless steel increases service life with maximum efficiency


PUMPS FOR AGGRESSIVE CHEMICAL MEDIA


CH430 series, the contaminants can have a particle size of up to 10mm.” Due to its compact and robust design, this stainless steel unit is versatile and can be installed and operated on either a stationary or mobile basis. Tis makes it ideal for use in the chemical industry and for the disposal of abrasive, chemical wastewater.


The CH430 series from Homa


TROUBLE-FREE PUMPING To ensure continuous pumping, individual components of the CH430 series, such as the motor housing, impeller and pump housing, are made of stainless steel 1.4436. Te strainer is installed on the pump housing and the pump block, which is made of highly resistant investment cast stainless steel, is fully floodable and sealed against pressurised


water. Tis allows aggressive media and chemicals with a pH value of 3 to 14 to be conveyed. Liquids can be transported at temperatures of up to 40°C. Levels of 60°C can also be sustained for brief periods.


Te pumps can be regulated and


monitored fully automatically by an additional controller: “Faults during a pumping process are automatically reported by the controllers to a mobile device via an app, and can therefore be rectified promptly,” reports Wild. Te fill level in the sump, the current measurement function and the thermal condition of the winding can be monitored. At the same time, maintenance intervals, delay times, start-up delays and rotational direction detection are displayed: “Tis ensures trouble-free operation when pumping chemically aggressive, abrasive media and chemicals,” Wild summarises.


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68