OPERATION & MAINTENANCE OF POWER PLANTS


Pumped storage plant


SWITCHGEAR SUCCESS STORY


power station with greener technology. Replacing equipment that was over 30 years old, the project included the UK’s fi rst installation of four modern Siemens generator circuit breakers that do not depend on the sulphur hexafl uoride (SF6


S


iemens has completed a major project with Drax Group to upgrade the infrastructure in the iconic Cruachan pumped hydro storage


in circuit breakers due to its good insulation capabilities but is classed as a greenhouse gas. Siemens’ innovative non-SF6


SF6 gas has traditionally been used )


gas commonly used in switchgear. Cruachan underground pumped hydro storage plant, also known as the Hollow Mountain, supplies up to 440MW of fl exible, on-demand electricity to the National Grid from four reversible turbines and has played a critical role in stabilising the UK’s electricity system throughout the Covid-19 pandemic.


The Cruachan dam reservoir


generator breakers use vacuum technology instead, making them safer and more environmentally friendly. T ere is no risk of gas leakages and no need for costly maintenance carried out by specialist engineers. Built from materials that are completely recyclable and hermetically sealed, the vacuum circuit breakers also have fewer moving parts, reducing wear and signifi cantly boosting reliability. Each vacuum interrupter has a mean time to failure of 77,000 years and can run through 10,000 operating cycles before a service is required – for Cruachan, that equates to 10 years of maintenance-free operation.


First UK hydro power station to implement environmentally friendly vacuum switchgear


Cruachan Power Station provides fast,


reliable power to the National Grid, as well as the fl exibility to absorb excess power - meaning it can start generating or pumping electricity within less than a minute, as well as providing system support services to maintain secure supplies of electricity and support more renewables like wind and solar to come onto the grid. Using a generator circuit breaker simplifi es Cruachan’s operational procedures, synchronising the load and avoiding extensive damage inside the transformer.


THE BIGGER PICTURE “With Cruachan playing a vital role in supporting the growth of wind power in Scotland and enabling further decarbonisation of the grid, it is only right that the infrastructure inside the power station is also environmentally friendly,” explains Ian Kinnaird, Drax’s head of Hydro. “Working closely with Siemens, we retrofi tted a fi rst-of-its-kind solution that uses innovative vacuum circuit breaker switching instead of SF6


gas. Not only has this removed any potential environmental impact and health and safety concerns caused by the previous, outdated switchgear – the new generator breakers are practically maintenance free, reducing costs. It’s a really neat solution.”


24 www.engineerlive.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52