5 Incubators, Freezers & Cooling Equipment
NU-677E Class II Type A2 animal handling safety cabinet
The NU-677E LabGard Class II Type A2 Biosafety Cabinet offers biological containment for animal research in a design that includes the access, mobility, and durability that vivariums need while minimising the
long-term cost of ownership. Your cage changing or other procedures should not be forced to fit inside a biosafety cabinet but rather the biosafety cabinet should be configured to fit around your process. That is why the NU-677E includes a 12-inch (305mm) work access opening to easily move cages in and out, a base stand whose height can be adjusted for the comfort of each technician, and castors that provide easy mobility. Engineered for long term service, this model is designed with a DC-ECM motor/ fan system to move airflow into the permanently mounted flexible HEPEX plenum with equal pressure, distributing particles evenly onto the upstream side of the HEPA filter. Even filter loading promotes uniform downflow velocity and extends HEPA filter life. Furthermore, an easily accessible pre-filter in the back wall helps trap animal hair and dander. Click to learn why NuAire biosafety cabinets are the safer choice for your animal research vivarium.
More information online:
ilmt.co/PL/7W3A 65867pr@reply-direct.com
NuAire Class II Type A2 biosafety cabinet
The LabGard NU-543E biosafety cabinet maximises return on investment for laboratories seeking containment at the best long-term cost of ownership. While a low purchase price has the potential to mask long- term expenses and a
higher lifetime cost, a larger
initial investment into a quality BSC can yield financial savings over the long term. The LabGard biosafety cabinet is designed using an optimally sized DC ECM motor/fan system to move airflow into the permanently mounted flexible HEPEX plenum with equal pressure, distributing particles evenly on the upstream side of the HEPA filter. Even filter loading promotes uniform downflow velocity and extends HEPA filter life, while the DC ECM motor compensates for filter loading to minimise filter changes. The FlowGard control system provides the user with a clear readout of the inflow based on the data input from the exhaust airflow sensor. For containment and cost-effectiveness, NuAire is the safer choice.
More information online:
ilmt.co/PL/jYB8 65869pr@reply-direct.com
NU-99729VFT Blizzard -86ºC ultra-low freezer solution
The NU-99729VFT Blizzard™ plugs in to nearly any laboratory with its ability to operate on a range of electrical currents from 100-230V/50-60Hz. Users can prioritise tight governance of the inner temperature by using the freezer in High Performance mode or use the more forgiving Energy Saving mode to prioritise efficiency. Samples are safely stored on steel shelves inside the freezer behind not only a quadruple-gasketed outer door but also a set of four single-gasketed and insulated inner doors. Beyond its modern aesthetics, the touch screen allows users to easily review records of not only the freezer’s operation but also a summary of the storage and withdrawal of the samples kept inside. Short-term performance is graphed on screen while long term data is downloaded via a USB port.
More information online:
ilmt.co/PL/N41L 65868pr@reply-direct.com
MULTI-LAYERED DEFENSE
AGAINST CULTURE CONTAMINATION The In-Vitrocell direct heat C02
Incubator offers complete CONTROL of the chamber ATMOSPHERE and CONTAMINATION to microbiological cell culture laboratories.
The best defenses are layered. The In-Vitrocell combines layers such as smooth chamber construction and constant HEPA fi ltration as defensive lines against contamination.
A choice of high heat or humidifi ed decontamination cycles on most In-Vitrocell models provides redundant protection against contamination of your cell culture.
STAINLESS STEEL CHAMBER The incubator chamber is made of stainless steel to make surface decontamination easy.
CLOSED-LOOP HEPA FILTRATION An air pump circulates existing chamber air through a HEPA fi lter for constant protection.
HIGH HEAT DECONTAMINATION A 145°C cycle can be run in only 8 hours while leaving fi lters and most sensors installed.*
*The RH sensor in the chamber must be removed for decontamination. Decon cycle available on specifi c models.
Coved Chamber Corners The In-Vitrocell uses a smooth, coved corner stainless steel chamber to make wipe down as easy as possible. Filters are located outside the chamber and further help create an easy to clean interior.
Scan to learn more.
NuAire, Inc. |
nuaire.com © Copyright 2025. NuAire, Inc. All Rights Reserved.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44