Summary of referenced test methods available from FTT: EN 455452
test method ref. T01 T02 T03
T04 T05 T06
T09.01 T09.02 T09.0304 T10 T11 T12 T13 T14 T15 T16 T17 Standard
EN ISO 45892 ISO 56582 ISO 56601
EN ISO 92391 EN ISO 119252 ISO 97052
EN 6033212 EN 60332324 Short description
Determination of burning behaviour by oxygen index – Part 2: Ambient temperature test Lateral flame spread
Reactiontofire tests – Heat release, smoke production and mass loss rate – Part 1: Heat release rate (cone calorimeter method)
Radiant panel test for horizontal flame spread of floorings Ignition when subjected to direct impingement of flame Furniture calorimeter vandalised seat
Tests on electric and optical fibre cables under fire conditions – Part 12: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW premixed flame
Common test methods for cables under fire conditions – Test for vertical flame spread of verticallymounted bunched wires or cables – Part 24: Procedures – Category C
Requirement set R22, R23, R24
R1, R2, R3, R4, R7, R11, R12, R17 R1, R2, R3, R5, R6, R7, R8, R9, R10,
R11, R12, R17, R19, R20, R21 R8, R10 R4, R5 R18
R15, R16 R15, R16 EN 503059.1:2002 Railway applications – Railways rolling stock cables having special fire performance – Test methods R15, R16 EN ISO 56592
EN 455452:2013 Annex C
NF X701001 NF X701002
EN 610342 EN 13501
(EN ISO 1182 and EN ISO 1716:2010)
EN 50305 EN 60695211 EN 606951110 Plastics – Smoke generation – Part 2: Determination of optical density by a singlechamber test Gas analysis in the smoke chamber EN ISO 56592, using FTIR technique Gas analysis for the 8 gases described on 3.1.5
Measurement of smoke density of cables burning under defined conditions – Part 2: Test procedure and requirements
Fire classification of construction products and building elements – Part 1: Classification using test data from reaction to fire tests
FTT Instrument EN ISO 45892 Oxygen Index Test
ISO 56582 Lateral Flame Spread Apparatus iCone® Calorimeter, Dual Cone Calorimeter
EN ISO 92391 Flooring Radiant Panel
EN ISO 119252 SingleFlame Source Test Apparatus ISO 97052 Large Scale Calorimeter
EN 603321 Vertical Flame Propagation Test for a Single Cable
EN 603323 Vertical Flame Propagation Test for Bunched Cables
EN 603323 Vertical Flame Propagation Test for Bunched Cables
R1, R2, R3, R4, R5, R6, R7, R8, R9, R10, NBS Smoke Density Chamber R11, R12, R17, R20, R21, R22, R23
R1, R2, R3, R4, R5, R6, R7, R8, R9, R10, NBS Smoke Density Chamber with FTIR Gas Analyser R11, R12, R17, R20, R21
R22, R23 R15, R16 R13 Railway applications – Railway rolling stock cables having special fire performance – test methods R15, R16
Fire hazard testing – Part 211: Glowing/hotwire based test methods Glowwire flammability test method for endproducts
Fire hazard testing – Part 1110: Test flames – 50 W horizontal and vertical flame test methods R25 R26 EN 5026723 Cable Toxicity Test Apparatus 3M Cube Smoke Test Apparatus
EN ISO 1182 NonCombustibility Apparatus, EN ISO 1716 Bomb Calorimeter
EN 603323 Vertical Flame Propagation Test for Bunched Cables
EN 60695211 Glow Wire Test Apparatus Vertical Flame Test Apparatus
Page no.
19 10 6
12 11 8
13 13 13 14 14 16 18
20 21
13 19 20
22
EN 45545-2:2013 – NEW F I R E C LASSIFICATIONS AND FIRE TES T METHODS FOR THE EUROPEAN RAILWAY INDUSTRY