This page contains a Flash digital edition of a book.
Ignitability EN ISO 4589­2 Oxygen Index Test


The Oxygen Index test is specified in EN 45545­2 for testing ignitability of listed and non­listed plastic products,


e.g. internal and external seals, isolators, and PCBs. It is also one of the most economical and precise quality control tests for combustible materials. Its ease of use together with high levels of precision has made this technique a primary characterising quality control tool to the plastic and electric cable industries and it has been specified by several military and transport groups. The technique measures the minimum percentage of oxygen in the test atmosphere that is required to marginally support combustion.


Figure 13: FTT Oxygen Index Test


The FTT Oxygen Index (OI) and Temperature Oxygen Index (TOI) offer many improvements such as the latest oxygen analyser technology for high accuracy, reliability and long operating life.


Table 12: Requirements concerning Oxygen Index test Requirement set Test parameter


R22


R23 R24


Oxygen content %


HL1 28


EN ISO 60695­2­11 Glow Wire Test


The EN 45545­2 specifies the EN ISO 60695­2­11 Glow Wire Test to test printed circuit boards without any attached technical equipment.


Inside this apparatus, a resistance wire is electrically heated to a specified temperature which is adjustable. The specimen tested is brought into contact with this glow­wire by a motor­driven sliding carriage. At the end of the prescribed time the specimen is automatically returned to the starting position. Observations and measurement are made to evaluate the ignition temperature which needs to be ≥ 850⁰C to meet the standard requirement.


The FTT Glow Wire Test Apparatus is fully automatic and features a 5.5" full colour touchscreen panel with HMI software control, and a built­in digital processor control unit to control glow­wire application time, test duration and to record flame timing.


Minimum Threshold HL2 28


Table 13: Requirements concerning Glow Wire Test Requirement set Test parameter


HL3 32


HL1 R25 Glow Wire Temperature °C


Figure 14: FTT Glow Wire Test Apparatus


Minimum Threshold HL2 850


HL3


FIRE TESTING TECHNOLOGY


19