REFRIGERANTS A case for conversion


Hydrofluorocarbon (HFC) gases, typically referred to as F-Gases, are manmade chemicals developed for use as refrigerants in the HVACR industry. They have been widely used as replacement fluids for ozone depleting gases such as chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs) as part of the phased- out programme under the Montreal protocol. Harley Bedford, technical sales engineer, Star Refrigeration looks at converting existing equipment to a lower GWP refrigerant gas.


A


lthough HFCs have no detrimental effect on the ozone layer they


contribute towards global warming if released into the atmosphere. Legislation has been introduced at a national and international level in order to combat the effects of F-Gases on climate change. The European F-Gas Regulation EC 842/2006 was implemented in 2006 and updated in 2014. It was a landmark ruling that provides a clear path for manufacturers, installers, specifiers and operators of refrigeration, air conditioning and heating equipment to phase down use of the most environmentally damaging refrigerants and introduce lower global warming potential (GWP) alternatives. The regulation refers to carbon dioxide equivalent as a measure of how


much a gas contributes to global warming. This uses CO2 with GWP of one as the baseline fluid for comparison.


To calculate the CO2 equivalent of a quantity of a refrigerant, the mass of gas is multiplied its global warming potential (GWP). For example, R404A (the widely used HFC refrigerant) has a GWP of 3922. This means


that 1kg of R404A contributes the equivalent of 3922kg of CO2 if released into the atmosphere. A table of commonly used refrigerants and their associate GWPs can be found in figure A. To mitigate the potential environmental impact of F-Gases, limitations around their use were introduced in the 2006 F-Gas Regulation. An update


40 March 2020


Figure A.


in 2014 added further measures to phase down fluorinated gases with high


GWPs in order to achieve a total reduction in equivalent CO2 of 79% by 01 January 2030. This regulation included a ban on the use of newly manufactured HFCs with a GWP greater than 2500 from 01 January 2020


for servicing refrigeration equipment with a CO2 equivalent charge greater than 40 tonnes.


This may appear to be a large figure but in the case of R404A, it relates to a system charge of just over 10kg. In practice terms it means that when there is a leak of refrigerant with a GWP higher than 2500 from a system, it will need to be replaced by reclaimed/recycled refrigerant of wthe same type or an alternative fluid. Whilst the purchase and use of reclaimed refrigerant is a viable short-


www.acr-news.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60