form during autoclaving. At the end of the autoclaving cycle, cooling is achieved by slowly releasing the steam through the venting valve, by allowing the steam to naturally condense inside the vessel or by sucking it out mechani- cally. Just before the pressure has reached atmospheric pressure, the venting valve is closed. The volume of the steam, as it conden- sates and changes into water, will shrink to 1700 times less than its gaseous size. This creates an immense vacuum inside the vessel, which must be replaced with sterile air. So, at the same time when the venting valve is closed, the sterile air inlet valve must be opened. Important: if at this point, non-sterile air is allowed into the autoclave, contamination of microorganisms may spoil the entire autoclave. When sterilising a grain substrate in a bulk vessel, the simplest version of the gravity cycle can be utilised, as explained above. The plateau at 121°C must be kept for 40 minutes or less, depending on the substrate recipe. Optional extras that shorten the cycle are: 1) creating a pre-vacuum before pressure increase to eradi- cate all gases before steam is injected, and 2) using a post-vacuum after cooldown to speed up the cooling process.


When sterilising grain or substrate spawn in bags - or bottles, boxes or other recipients - the gravity cycle is not the best option. When steam is injected into the autoclave, it is supposed to gradually replace the air in every part of the substrate during the pressure build-up. In an open mix such as a bulk vessel, this is easy as all pore spaces are open and there are no obstructi- ons anywhere. But in an autoclave filled with bags the situation is totally different. The bags are being compressed as the steam builds up the pressure, but there is no free exchange of steam and air between the bag and the surrounding space in the autoclave. The gases inside the bags get trapped and act as an insulator: where they prevent the steam from penetrating the substrate, the heat transfer is much less efficient. The heat will only slowly pass through the plastic to reach the substrate particles on the inside. In large bags filled with grain, this process can take as much as 240 minutes. As a result, the temperature inside each bag changes gradually, with the outer layers heating up faster. This temperature gradient causes quality differences inside each bag and an overall quality drop. There are only two possibi- lities to get rid of this problem: 1) use smaller bags or 2) apply a vacuum sterilisation cycle.


The liquids cycle


The liquids cycle is used to sterilise liquids. Examples are liquid spawn substrates and agar


bottles. It is comparable to the gravity cycle, with one diffe- rence: during heating and cooling, the temperature must be gradually and slowly increased and decreased. If not, the bottles will burst and/ or the liquid will start to boil violently, causing serious problems.


The vacuum cycle


The vacuum cycle or pulsating cycle (see fig. 4) is a rather complicated sterilisation cycle. It has been developed specifically for sterilising porous and bagged goods, such as pre-bagged spawn substrate. The cycle works as follows: the pressure is increased and decreased in a number of pressure pulses, followed by a stable maxi- mum temperature plateau at 121°C or more. During the pulses, the air and gasses that are present inside the bags – or bottles, boxes, etc – are replaced by steam by force. This way, the time for every particle to reach 121°C is shorter and the temperature plateau can be much shorter than during a gravity cycle: 30 minutes or less, depending on the type of substrate and packaging, and positioning of the bags in the autoclave. Without trapped gasses, there is no temperature gradient inside the bags. This is very


beneficial for the quality of the end product, which reaches similar quality levels as bags produced with bulk sterilisation, or as liquids sterilisation.


There is no general type of vacuum cycle. The amount of pressure pulses, the height of the pulses, etc. : all parameters depend on the situation. Trial-and-error is the only way to work out an optimally working vacuum sterilisa- tion cycle. These are a few important observati- ons: 1) The pressure increase through steam supply is the most crucial point of the cycle. If this increase is not fast enough, the steam will not be able to penetrate deep into the bags. That means the steam generator must be able to supply sufficient steam and that the piping, valves and filters must be operating perfectly. 2) If the pressure increases too fast, the bags will compress. If the pressure decreases too fast, the bags will explode. 3) The difference between the top and bottom of a pulse must be at least 0.3 bar. 4) When using this type of autoclaving cycle, permanent measurements inside the bags during each cycle are essential.


MUSHROOM BUSINESS 35


Fig 3. Infl uence of air on sterilisation.


Fig 4. Vacuum sterilisation cycle.





Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44