Introducing the EMS


the solution for


Evaporation-Controlled Automated Embedding and Polymerization


• Automates embedding • Reduces hands-on time


• Minimizes exposure to hazardous and irritating chemicals


• Reduces solvent and resin use


• Facilitates the processing of up to 52 samples in one instrument run


• Prevents specimen loss Yeast cells were fixed with


glutaraldehyde in cacodylate buffer, washed in distilled


water and postfixed with 1% KMnO4 in distilled water


The EMS POLY III is an instrument for the embedding of specimens by the proper combination of pressure and temperature. Central to the instrument is a specimen chamber that is temperature controlled and which can be heated up from room temperature to 70°C. The pressure in the chamber can be reduced from ambient pressure to a controlled level with an inbuilt vacuum-pump. The instrument chamber accepts up to 52 BEEM specimen vials, and features preset programs which can be modified according to the user’s preference. In the presets pressure and temperature settings have been coordinated and optimized for an efficient removal of solvent from the specimens. Bulk removal of solvent is followed by steps for the thorough removal of trace amounts.


As a practical approach the instrument can be loaded by the end of a workday and (when using acetone or propylene oxide) by the next morning the vials are ready for polymerization after the vials have been topped up with pure resin.


A lengthy and sometimes tedious manual procedure now reduced to a few simple steps.


EMS has it!


CONTACT US FOR MORE INFORMATION...


P.O. Box 550 • 1560 Industry Rd. Hatfield, Pa 19440 Tel: (215) 412-8400 Fax: (215) 412-8450 email: sgkcck@aol.com or stacie@ems-secure.com


Facilitates the processing of up to 52 samples in one instrument run.


A choice of 3 embedding programs in the EMS POLY III for 3 different solvents. They have been pre-programmed for general use but the user can change the programs to fit specific specimens.


www.emsdiasum.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68