Product name – fuel type – boiler type – output range – maximum gross efficiency –
NOx emissions Vitoplex 100 – Oil/gas – Oil/ gas – 150-2000kW – 91.7 per cent
– 80ppm Vitoplex 200 – Low temperature oil/gas – Low temperature oil/gas –
90-1950kW – 92.3 per cent – 80ppm Vitoplex 300 – Low temperature oil/gas – Low temperature oil/gas –
80-2000kW – 92.9 per cent – 80 ppm Vitorond 100 – Oil/gas – Oil/gas
– 40-100kW – 93.2 per cent – 80ppm Vitorond 200 – Oil/gas – Oil/ gas – 125-1080kW – 92.8 per cent
– 80ppm Vitocrossal 200 – Gas – Condensing – 87-620kW – 97.9 per
cent – <39ppm Vitocrossal 300 – Gas – Condensing – 26kW-1.4MW – 97.8
per cent – <39ppm Vitoradial – Oil – Condensing –
101-545kW – 97.5 per cent – n/a Vitomax 100 – Oil / gas – Steam
– 650-6000kW – 84 per cent – n/a Vitomax 200 – Oil / gas – Steam
– 520-18200kW – 81 per cent – n/a Vitomax 300 – Oil / gas – Steam
– 1860-5900kW – 86 per cent – n/a Vitodens 200 – Gas – Condensing
– 45-150kW – 98 per cent – <39ppm Vitobloc 200 – CHP – CHP – 20-549kW – 92.7 per cent – n/a
Product name and size Vitoplex 100 – Floor- standing: 1460mm (w) x 1690mm (h)
x 2115mm (d) Vitoplex 200 – Floor- standing: 1450mm (w) x 1690mm (h)
x 2355mm (d) Vitoplex 300 – Floor- standing: 1460mm (w) x 1690mm (h)
x 2320mm (d) Vitorond 100 – Floor- standing: 565mm (w) x 1110mm (h)
x 915mm (d) Vitorond 200 – Floor- standing: 1090mm (w) x 1480mm (h)
x 2270mm (d) Vitocrossal 200 – Floor- standing: 1200mm (w) x 1985mm (h)
x 1820mm (d) Vitocrossal 300 – Floor- standing: 1160mm (w) x 1792mm (h)
x 2653mm (d)
Vitoradial – Floor-
standing: 575mm (w) x 1145mm (h) x 1195mm (d)
Viessmann case study Project: Kings Cross redevelopment, London
Equipment: 3 x Vitomax 200 LW boiler 10 MW , 1 x CHP unit 1.8 MW, 2 x 75,000 litre thermal stores Contractor: Vital Energi
At 67 acres, King’s Cross Central is the largest mixed use development in central London for 150 years. When completed, the plot will house 25 new office building, 20 new streets, 10 new major public spaces, and 1,900 new homes, as well as 20 fully restored historic buildings and structures. As Europe’s largest city centre regeneration scheme, the site now even has its own postcode; N1C.
To provide efficiency and keep early capital investment and maintenance costs minimal, Vital Energi has been furnishing King’s Cross Central’s energy centre with technology in stages, so as to match the heating and hot water demands of the development’s occupants as construction grows. The project started with a temporary energy centre containing three Viessmann Vitomax 200 LW boilers. With a new plant completed, the 2.9 MW units were transferred to perform the same role at another new site.
Now completed, the centre contains three 1.8 MW CHP units and three 10 MW gas-fired boilers to provide heating, hot water and locally generated electricity.
Vitomax 100 – Floor- standing: 1480mm (w) x 1680mm (h)
x 2480mm (d) Vitomax 200 – Floor- standing: 1590mm (w) x 1830mm (h)
x 2500mm (d) Vitomax 300 – Floor- standing: 2070mm (w) x 2350mm (h)
x 3830mm (d) Vitola – Floor-standing: 594mm
(w) x 795mm (h) x 1052mm (d) Vitodens 200 – Wall-hung: 450mm
(w) x 850mm (h) x 360mm (d) Vitobloc 200 – Floor- standing: 1600mm (w) x 2000mm (h) x 3980mm (d)
Installation aids available Skid-mounting kits Flue kits Prefabricated hydraulic pipework
Controls available Weather compensation Cascade control Sequencers Integrating controls
Other products available Solar thermal systems Solar PV
Thermal storage vessels / cylinders CHP Biomass boilers Air source heat pumps Ground source heat pumps Split heat pumps Fuel cell heating
Unique selling points Unique patented heat exchanger
and burner technology Integrated system solutions for all
applications and fuels Condensing boilers from 45 to
1.4MW Condensing oil boilers High efficiency non-condensing
boilers from 80 to 20,000kW True three-pass boilers in the
Vitoplex, Vitoradial and Vitomax Brief company history
Country of origin: Germany Founded in: 1917 Established in the UK in: 1979 Group turnover: £1.89bn No. of employees in the UK: 94
The energy centre delivers heating and hot water to the King’s Cross site with two Vitomax 200 10 MW boilers. It continued to do so until the site had sufficient daily demand to require the currently installed single CHP 1.8 MW engine. The system delivers hot water to two 75,000 litre thermal stores.
Further installations to complete the energy centre comprise of a third Viessmann Vitomax boiler and two additional CHP units.
Daily news update at
www.heatingandventilating.net
Supplement to HVR | September 2014 | 15
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60