Monitoring water quality: a challenge for spectroscopic technology


Monitoring water quality has become vital, both for the environment and to maintain drinking water quality. This article details why UV-Vis spectrophotometry is being increasingly used in water monitoring


W


ater is essential to human survival and is critical to food security,


environmental conservation, and human health. However, due to various human activities, such as the use of agricultural fertilisers and industrial pollutants, water quality has been compromised. Therefore, assessing water quality has become vital across both environmental monitoring and ensuring the quality of drinking water.


UV-Vis spectroscopy for online water monitoring Traditional methods for assessing water quality parameters include chemical, biological, and physical approaches. While chemical methods require bulky and expensive equipment and a large number of reagents, biological methods suffer from lower accuracy and sensitivity1. Physical methods, on the other hand, include spectral remote sensing technology in the UV and visible wavelengths, such as UV- Vis spectrophotometry, which is increasingly used for rapid water quality assessment. UV-Vis spectrophotometry


works on the principle of the correlation between the absorption of specific light wavelengths by a substance and its concentration2. The method does not require sample filtrations, is reagent-free, and provides fast measurements of water quality in real time.


12 Photonics Frontiers 2023


Among the parameters that can be measured using UV- Vis spectrophotometers are UV254, colour, nitrate, depleted oxygen content (DOC), total oxygen content (TOC), and the spectral absorption coefficient (SAC254). In recent years, additional parameters have been included in water quality monitoring using online UV- Vis spectrophotometers2, such as measurements of dissolved organic matter3, chemical oxygen demand (COD)4 in water bodies, and disinfectant in drinking water5.


Single-wavelength and multiwavelength detectors There are two types of spectral sensors used in water analysis: single-wavelength (SW) sensors and spectrophotometers. SW sensors generally consist of a bandpass-filtered single photodetector and a light source that emits in the targeted wavelength and is absorbed by the substance to be detected. On the other hand, spectrophotometers use a broadband light source, a diffraction grating that separates light into its wavelength components and directs it towards a linear array photodetector.


“When using a UV- Vis spectral or full- spectrum sensor, it is crucial to choose the most suitable broadband light source”


Generally, when comparing


the performance of full-spectrum and SW sensors, the latter can measure parameter variations during certain periods but may not compensate for the particle effect accurately, specifically when comparing the results with the standard laboratory procedures and measurements. On the contrary, spectrophotometers provide better particle compensation and can be calibrated to specific locations with higher accuracy. They are


better for precise applications, such as real-time water and treatment process monitoring6.


Light sources for UV-Vis spectroscopy When using a UV-Vis spectral or full-spectrum sensor, it is crucial to choose the most suitable broadband light source. The light source needs a suitable spectrum, brightness, reliability, short to no warm-up time, long lifetime, low power consumption and compactness. Although LEDs are widely used in many applications, they are not as useful in UV-Vis spectrophotometry due to their narrow-spectrum light and limited available wavelengths. Instead, broadband emitters like deuterium lamps and xenon flash lamps are preferred. Deuterium lamps have a limited emission spectrum and require long warm-ups, but are preferred for lab-based benchtop devices due to their lower peak-to-peak variation. Xenon flash lamps offer a wider wavelength range, allowing for the simultaneous detection of a high number of water parameters.


Hamamatsu’s Xenon Flash Lamps for portable spectrophotometers Using their know-how in vacuum device fabrication and electronics integration, Hamamatsu Photonics developed the most advanced Xenon Flash Lamps for UV-Vis- NIR portable spectrophotometry and online water monitoring.


These devices are available as


stand-alone emitters or modules with an integrated trigger socket and power supply for easy integration. Hamamatsu’s Xenon Flash Lamps feature instantaneous high peak output, a compact design, low heat generation, and a continuous emission spectrum from 160nm up to mid-infrared wavelengths, making it the ideal light source for miniaturised instruments. These lamps have a guaranteed lifetime of 10 billion flashes and offer output powers spanning from 2W up to 60W. In conclusion, monitoring water quality is crucial to maintaining human health, food security, and environmental conservation. While traditional sampling


programmes provide only a partial understanding of water quality, UV-Vis spectroscopy offers real-time, accurate, and cost-effective measurements of various water parameters. UV-Vis spectrophotometry is becoming increasingly popular in water quality assessment because it allows for precise measurements of various water parameters. Online UV-Vis spectrophotometers are particularly useful for real-time monitoring of water quality, and their performance can be improved by choosing the most suitable broadband light source. l


References 1


2 https://doi.org/10.1080/05704928.2015.1010205


Guo, Y.; Liu, C.; Ye, R.; Duan, Q. Advances on Water Quality Detection by UV-Vis Spectroscopy. Appl. Sci. 2020, 10, 6874.


3


Li, P.; Hur, J. Utilization of UV-Vis spectroscopy and related data analyses for dissolved organic matter (DOM) studies: A review. Crit. Rev. Environ. Sci. Technol. 2017, 47, 131–154.


4


Liu, F.; Zheng, P.; Huang, B.; Zhao, X.; Jiao, L.; Dong, D. A review on optical measurement method of chemical oxygen demand in water bodies. In Proceedings of the International Conference on Computer and Computing Technologies in Agriculture, Beijing, China, 27–30 September 2015; pp. 619–636.


5


Hossain, S.; Chow, C.W.; Hewa, G.A.; Cook DHarris, M. Spectrophotometric online detection of drinking water disinfectant:A machine learning approach. Sensors 2020, 20, 6671.


6


Shi, Z.; Chow, C.W.; Fabris, R.; Liu, J.; Jin, B. Alternative particle compensation techniques for online water quality monitoring using UV–Vis spectrophotometer. Chemom. Intell. Lab. Syst. 2020, 204, 104074. [CrossRef]


Further information


For more information about Hamamatsu’s solutions for the Energy/Environment sector, visit: www.hamamatsu.com


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58