HVAC


This highly-experienced team will scrutinise and photograph every area of risk and will produce a full report proposing and prioritising mitigation measures. This will give owners, operators and managers peace of mind that their plant may be operated safely and that all relevant guidance and legislation is supported once any identified hazards are rectified.


WHA ARE THE TYPICAL FINDINGS OF A TBHRA?


Unlike a vehicle MOT, a TBHRA does not pass or fail a steam system, but instead highlights hazards and the potential risk and then proposes measures to rectify any issues.


According to INDG 436 “a risk assessment does not need to include excessive detail”, but issues highlighted can include boiler specification, location, operation and condition, poor record keeping, lack of suitable/relevant training or trained operator absence cover, shortage of plant drawings and manuals, control system reliability, ventilation issues, poor/no suitable operational procedures, water quality issues, etc.


BEYOND THE TBHRA?


Once its assessment is completed and delivered, there is no commitment by the customer to involve Fulton in any post-assessment remedial works. But the document does highlight areas of the steam system that require attention and will prioritise the risk they pose from high priority (red) to lower priority (green). The assessment must also be made available to the boiler operator and, in the event of the sale of equipment, the new owner/operator. However, unlike a MOT, a TBHRA is a live document that should be updated on an ongoing basis when any changes or modifications affecting the operation of a boiler occurs. This can include personnel changes, additional training, physical changes including boiler/burner upgrades, legislation amendments, etc. Fulton can offer support to the customer once the TBHRA has been completed, or during or after the annual review. This support can be provided onsite or via telephone or video conference assistance once the review is completed.


A TBHRA also offers excellent value for money because it not only highlights areas of potential risk for owners, operators and managers, but can also identify where enhancements to the steam system could lead to improved energy efficiency. For example, the cost to replace an old, inefficient or dangerous burner could easily be offset within a few years by the fuel savings achieved through the upgrade.


For further information on Fulton’s technical boiler house risk assessment package, call the office on +44 (0)117 972 3322, email aftercare@fulton.co.uk or visit www.fulton.co.uk.


Fulton


www.fulton.co.uk T: +44 90) 117 972 3322


FACTORY&HANDLINGSOLUTIONS | NOVEMBER 2020 19


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52