UPSI-2406DP1 is switched off by deactivating the battery accordingly. By reducing the BMS own power consumption to a minimum, safety and shelf life of the DC UPS also increases significantly. The integrated minimum load


detection with the help of a load sensor at the output switches off the DC UPS when the threshold value is not reached (no load) so as not to use up energy unnecessarily. In addition, the UPSI-2406DP1 has overcurrent and reverse polarity protection as well as deep discharge protection. Pre-programmable for self- sufficient operation The management software HID


Control Center – available for free download – is for setting and preprogramming various parameters of the DC UPS system as well as real- time monitoring with charge status display. The parameters that can be set include: Load sensor (mA), shutdown delay, maximum backup time, minimum load capacity before system start, ignition timer and restart delay. The data connection to the IPC system takes place via the integrated USB interface. Shutdown & Reboot function for IPC systems In the event of a ‘PowerFail’, the DC


UPS signals the failure of supply voltage via integrated interface, so that a controlled shutdown of the computer system can be initiated and valuable data can be saved. The integrated reboot function of the DC- UPS automatically initiates the restart of the supplied IPC after the supply voltage has returned, without the need for costly on-site intervention by service staff, e.g. with completely


UNINTERRUPTIBLE POWER SUPPLIES –


MADE IN GERMANY Bicker Elektronik offers a broad portfolio of reliable DC UPS solutions for uninterruptible power supply. Maintenance-free Supercaps, long-life and safe LiFePo4 and lithium-ion battery packs or classic lead-acid batteries are used for energy storage – depending on the area of application and requirements. Well equipped with numerous interfaces and functions, computer systems and DC loads can be supplied with fail-safe power. www.bicker.de/dc-ups


The management software HID Control Center – available for free download – is for setting and pre- programming various parameters of the DC UPS system as well as real-time monitoring with charge status display


self-sufficient computer systems at inaccessible locations. Tested according to IEC/UL/CSA 61010-1 / -2-201 The DC UPS system UPSI-2406DP1 has


international safety certifications for worldwide use: ETL UL61010-1 / -2-201, CSA C22.2 61010-1-12 / -2-201, CB Scheme IEC 61010-1 /-2-201. Front interfaces and DIN rail mounting All inputs and outputs are arranged on


The new 24VDC emergency power supply UPSI-2406DP1 in a robust DIN rail housing is ideally suited for long-term 24/7 continuous operation


the front of the UPSI-2406DP1. In addition to the connections for input and output voltage with status LED, this includes a relay contact (PowerFail), an RS232 communication interface and a USB interface. The compact and high- quality aluminium housing (63 x 120 x


100 mm) is equipped with a DIN rail holder on the rear for flexible and quick top-hat rail mounting. Comprehensive service & support In addition to the three-year device


warranty, Bicker Elektronik GmbH guarantees long-term availability of at least 5 years on the new DC UPS UPSI- 2406DP1. In particular, applications with a correspondingly long runtime benefit from optimal investment protection with first-class design-in advice and extensive service & support from the specialists at Bicker Elektronik. On request, the development engineers at Bicker Elektronik can implement customer-specific and special solutions and also offer extensive laboratory and measurement services for complete customer systems. Bicker UPSI-2406DP1 – All features at a glance • 24V DC UPS module with integrated Li-Ion battery pack


• Long-life Lithium-Ion cells • High energy density - long backup times


• Intelligent input current detection • 'Power sharing' between charger and load


• Regulated output voltage in backup mode


• 'Smart Battery Lock' and minimum load detection


• Relay contact for power fail • Power fail timer function • USB & RS232 interface • HID Control Center software included • Shutdown & Reboot function for IPC • Battery fuel gauge • Approved to IEC/UL/CSA 61010-1 / -2-201


• Excellent price-performance ratio • 3 years warranty For further information please visit: www.bicker.de/en/upsi-2406dp1


Bicker Elektronik www.bicker.de/dc-ups


/ PROCESS&CONTROL PROCESS & CONTROL | OCTOBER 2020 15


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44