INDUSTRY FOCUS CHEMICALS & PHARMACEUTICALS HEAT EXCHANGERS WITH THE ‘S’ FACTOR
enforce this. For example, pharmaceutical, cosmetic
and medical ingredients often have very tight temperature tolerances, requiring specific operations to be carried out at specific temperatures, while applications such as the production of Purified Water and Water for Injection (WFI) require the highest standards of hygiene. However, many of today’s pharmaceutical manufacturers are going above and beyond this, reducing their contamination risk further through the use of robust procedures and well designed equipment. One such example is the improved HRS
Avoiding cross-contamination in the
pharmaceutical industry is essential to ensure the integrity of healthcare products
and medicines. Matt Hale, international sales &
marketing director, HRS Heat Exchangers, says the company’s S series of heat exchangers are more than up to the job...
C
ross contamination in the pharmaceutical industry is not just an
issue for those working in it, but for the wider public as a whole. As general awareness of the potential issues has increased, more and more questions are being asked of manufacturers and health professionals about the safety, integrity and potential side effects of a range of products and medicines. Understandably,
threat for any type of bioprocessing laboratory or manufacturing facility2 Thanks to the increasing use of
.
outsourced production, new technologies and continually evolving biological and microbiological techniques, ensuring safe pharma manufacturing has become increasingly complex3
. ‘The S Series is fitted with a double tube
most of the attention on contamination in pharmaceutical manufacturing and processing is focused on either cross contamination between products or agents, or from the spread of agents, such as biological cultures, within a facility. In fact, the potential harm of biological and other agents escaping from production sites has recently been highlighted by environmental pollution from antibiotics in a number of countries, which is believed to be a contributing factor to rising levels of antibiotic resistance around the world1
. Furthermore, viral contamination can also be a serious 22 FEBRUARY 2019 | PROCESS & CONTROL
plate to overcome the potential issue of contamination between the product side and the service side materials’
However, designers, manufacturers and operators need to take concerns seriously as even relatively small issues can quickly escalate, not only in terms of the actual effects
they may have on consumers, clients and the environment,
but also the potential damage they can cause to company
reputation and valuable brands. Attention also needs to be given to
the potential contamination of (and from) environmental factors used in the production and processing of pharmaceuticals, such as water and air used for process heating, cooling or sterilisation. Obviously, the best option is to prevent contamination in the first place and there are many regulations to
One of the new S Series pharma grade heat exchangers from HRS
S Series of corrugated multi-tube heat exchangers. The S Series is fitted with a double tube plate to overcome the potential issue of contamination between the product side and service side materials which is a prerequisite for some pharmaceutical applications. This design prevents contamination and provides leak detection while offering all the usual benefits of HRS Heat Exchangers’ normal corrugated tube design, including reduced fouling, improved heat transfer and reduced pressure drop. All S Series models also feature an expansion bellows to absorb different expansion rates between the shell and inner tubes. Individual units are available with surface areas from 1.3 to 6.8 m2
, and units can be combined in a
frame for larger applications. Surface finishes range from 0.4 to 0.8μ for pharmaceutical and hygienic industries and descaled for all industrial applications. The new S Series of multi-tube shell
and tube heat exchangers builds on the strengths and reputation of the previously named HRS F Series of hygienic heat exchangers, but introduces three distinct models aimed at different industrial sectors where cross contamination and leak detection are important: • HRS SP Series – Specifically targeted
Environmental impact of antibiotics production sparks global concerns:
http://www.globalcause.
co.uk/antibiotic- resistance/environmental -impact-of-antibiotics- production-sparks- global-concerns 2
1
Controlling contamination in bioprocessing:
https://www.pharmaceu tical-networking. com/controlling- contamination-in- bioprocessing/ 3
https://www.pharma
focusasia.com/strategy/ risk-management
at pharmaceutical use, this multi-tube heat exchanger is ideal for WFI and purified water production, as well as many other uses. • HRS SH Series – Multi-tube heat
exchanger for hygienic uses such as cosmetics and personal care, food and beverage manufacture and potable water. • HRS SI Series – A multi-tube heat
exchanger for industrial applications such as chemicals, oil and environmental water applications. However stringent the hygienic
requirement of your process are, there is a new S Series heat exchanger to reduce the cross contamination risk during processing.
HRS Heat Exchangers
www.hrs-heatexchangers.com
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52