Pneumatic Timer - Digital Series
Pneumatic Digital Timer Panel Mount
Technical information Pressure range:
Temperature range: Mounting:
Reset:
Operating Medium:
Accessories, page 7.
Digital pneumatic time counters retain the last timed value upon loss of air.
On air connection to the timing port, pneumatic pulses are generated and registered on a two-line display every second or minute.
There are two types of output upon reaching the preset value.
Standard or automatic.
Please see data sheets for further information.
ATEX Versions Available QY002 2-6 bar 0°C +60°C Panel mount
Pulse signal to port Y, min pulse length 180ms (Pneumatic reset versions only)
5 micron filtered, non- lubricated compressed air
Description
3 digit seconds timer 3 digit minutes timer 5 digit seconds timer 5 digit minutes timer
5 Digit seconds timer with automatic reset
5 digits minutes timer with automatic reset
Ports
Order code 53.K21.03.00
53.K22.03.00 53.K52.05.00 53.K54.05.00
53.K65.05.10 53.K66.05.10
M5
The PT pneumatic timer is a reliable, robust, proven product that operates from -30°C to +70°C.
Valve connection: ON delay, OFF delay, or a diverter valve function.
The PT41 pneumatic timer is unique. It is the only timer where timing commences upon completely removing compressed air from the control port.
Pneumatic Timer -
52.SB Series
Set and Forget Timer M5 Bottom Ported
Technical information Pressure range:
Temperature range: QY003 1.5-8 bar -10°C +60°C
Mounting: Panel / Subplate mount Reset:
Operating Medium:
Automatic by removal of pressure control port 12 or 10
5 micron filtered clean dry, non-lubricated compressed air
Description
0.5 to 60 seconds (12) 1 to 120 seconds (12) 3 to 180 seconds (12) 0.5 to 60 seconds (10) 1 to 120 seconds (10)
Ports
Order code
52.SB20.060
52.SB20.120
52.SB20.180
52.SB21.060
52.SB21.120 M5
Pneumatic Timer - PT Series
PT Pneumatic Timer Vertical Surface Mount
Technical information Pressure range:
Temperature range:
Operating Medium:
QY007
1.4-9.5 bar -30°C +70°C
Mounting: Upright vertical mount Reset:
Removal of control pressure
5 micron filtered air or non-aggressive gas, non- lubricated
Description
Timing starts on application of air to control port C, valve switches on time out
Timing starts by removal of air to control port C, valve returns to its spring condition on time out
0.1 to 1 second 0.5 to 5 seconds 1.5 to 15 seconds 5 to 50 seconds 20 to 200 seconds 1 to 300 seconds 1 to 10 minutes 3 to 30 minutes 6 to 60 minutes
Ports Pneumatic Timer -
52.SN Series
Set and Forget Timer 1/8 NPT Side Ported
Technical information Pressure range:
Temperature range: QY004 1.5-8 bar -10°C +60°C
Mounting: Panel / Base mount Reset:
Operating Medium:
Automatic by removal of pressure control port 12 or 10
5 micron filtered clean dry, non-lubricated compressed air
Description
0.5 to 60 seconds (12) 1 to 120 seconds (12) 3 to 180 seconds (12) 0.5 to 60 seconds (10) 1 to 120 seconds (10)
Ports
(10) The OFF is delayed. The output valve is positive while timing and negative on timeout. Normally open timing.
(12) The ON is delayed. The output valve is negative while timing and positive on timeout. Normally closed timing.
Order code
52.SN20.060
52.SN20.120
52.SN20.180
52.SN21.060
52.SN21.120 1/8 NPT
Order code PT31*
PT41*
*A *B *C *D *E *K *F *H *I
1/8 NPT
(10) The OFF is delayed. The output valve is positive while timing and negative on timeout. Normally open timing.
(12) The ON is delayed. The output valve is negative while timing and positive on timeout. Normally closed timing.
Configuration: Isolated control pressure or same supply and control pressure. See data sheets for further information.
sales@impulseautomation.co.uk |
www.impulseautomation.co.uk | +44 (0) 1264 364194
5
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126