Pneumatic Timer - 56 Series
KUAX Pneumatic Clock Timer Panel or Surface Mount
Technical information Pressure range:
Reset: QY000 0-10 bar
Temperature range: -10°C +60°C Mounting:
Air consumption: Description
Surface mount bracket sold separately, page 7.
0.3 to 10 seconds 3 to 100 seconds 0.3 to 10 minutes 3 to 100 minutes 0.3 to 10 hours 3 to 100 hours Ports
Panel mount
Automatic - by removal of pressure (Control port 12)
Approx. 9 l/min Order code
56.S21.010 56.S22.100 56.M23.010 56.M24.100 56.H25.010 56.H26.100 M5
The 56 series pneumatic timer has a geared timing mechanism for precision, designed with conventional sweeping timing hands and a large rotary knob for quick and easy operation.
ON or OFF delay timing is achieved by blocking the respective ports with a blanking plug. Set the time by adjusting a large rotary knob. A black timing hand shows the preset time, and a red timing hand the remaining time.
Pneumatic Timer - ON Delay Timing
Pneumatic Mini Timer Panel or DIN-Rail Mount
Technical information Pressure range:
Temperature range: Mounting:
Reset:
Operating Medium:
QY005 2-6 bar 0°C +60°C Panel mount
Automatic - by removal of pressure port 1
5 micron filtered clean dry, non-lubricated compressed air
Description 0.2 to 3 seconds
DIN-rail mount sold separately, page 7.
2 to 30 seconds 8 to 120 seconds 20 to 300 seconds
Ports
Order code 51.020.33.00
51.020.03.00 51.020.34.00 51.020.30.00 M5
Set the pneumatic timer by adjusting the front rotary knob to the desired set- point. Two vertical scales indicate the set time and the remaining cycle time.
The ON is delayed. The output valve is negative while timing and positive on timeout. Normally closed timing.
ATEX Versions Available Accessories, page 7.
Automatic reset modules are used alongside ON delay timers to create continuous pneumatic pulsed output signals from 0.2 to 2 seconds. The ON delay timer separates these pulsed outputs.
Automatic reset timers generate output signals that repeat while air is connected. Removal of air stops and resets the circuit. The front rotary knob sets the desired output time and, when pulled, resets the device.
ATEX Versions Available
Pneumatic Timer - OFF Delay Timing QY009
Pneumatic Mini Timer Panel Mount
Technical information Pressure range:
Reset:
Operating Medium:
2-6 bar
Temperature range: 0°C +60°C Mounting:
Panel mount
Automatic - by removal of pressure port 12
5 micron filtered clean dry, non-lubricated compressed air
Description 2 to 30 seconds
20 to 300 seconds Ports
Accessories, page 7.
Set the pneumatic timer by adjusting the front rotary knob to the desired set- point. Two vertical scales indicate the set time and the remaining cycle time.
The OFF is delayed. The output valve is positive while timing and negative on timeout. Normally open timing.
ATEX Versions Available
Order code 51.021.03.00
51.021.30.00 M5
Pneumatic Timer - Reset Module
Pneumatic Automatic Reset Module Panel Mount
Technical information Pressure range:
Reset:
Operating Medium:
QY006 2-6 bar
Temperature range: 0°C +60°C Mounting:
Panel mount
Automatic - by removal of pressure port 1
5 micron filtered clean dry, non-lubricated compressed air
Description 0.2 to 2 seconds
Ports
Order code 51.020.35.00
M5
4
sales@impulseautomation.co.uk |
www.impulseautomation.co.uk | +44 (0) 1264 364194
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82 |
Page 83 |
Page 84 |
Page 85 |
Page 86 |
Page 87 |
Page 88 |
Page 89 |
Page 90 |
Page 91 |
Page 92 |
Page 93 |
Page 94 |
Page 95 |
Page 96 |
Page 97 |
Page 98 |
Page 99 |
Page 100 |
Page 101 |
Page 102 |
Page 103 |
Page 104 |
Page 105 |
Page 106 |
Page 107 |
Page 108 |
Page 109 |
Page 110 |
Page 111 |
Page 112 |
Page 113 |
Page 114 |
Page 115 |
Page 116 |
Page 117 |
Page 118 |
Page 119 |
Page 120 |
Page 121 |
Page 122 |
Page 123 |
Page 124 |
Page 125 |
Page 126