INDUSTRY COMMENT Ask the Expert Simon Butcher senior technical services manager for


Smith’s Environmental Products examines the challenges in heating historic buildings


Finding a way to provide heating in historic buildings is a challenge that is not easily overcome. The reluctance to detract from the aesthetic and architectural fabric of culturally significant buildings is understandable. Often it is not just a desire to avoid ungainly heat emitters but also a requirement. A good example of such a dilemma was presented to me at Grittleton House near Cirencester. This project required a heating solution that can work on biomass and their oil boiler supplied system. Consideration was given as to how the new heating system could be integrated into the building without altering the aesthetics of the rooms. Beneath the floors was hidden brick ducting running from the service passages up into the impressive reception rooms and


hall. To capitalise on the pre-existing ducting Smith’s Caspian UVC fan convectors were installed in the subterranean wine cellars and service passages beneath the stately home. Ducts were employed to transfer the warm air from the Caspian UVC fan convectors to heat the vast spaces above. Other ducting was used to provide the return air back into the underfloor passages. The use of Caspian UVC meant that the brief of providing heat emitters that could heat the very large spaces quickly whilst avoiding having any emitters within the historical spaces was achieved.


‘Hidden’ solutions in historic buildings


A similar solution was required at Liverpool Town Hall where 20 Caspian UVC concealed units were hidden behind panels in the walls of various rooms within the building, enabling visitors to feel the effects of the heat without having to see the products. The concealment of the fan convectors has been done without any compromise to the internal fabric of the building or to the fan convection heating. In north London at the Grim’s Dyke hotel Caspian UVC fan convectors were installed in a number of rooms, including the restaurant and the prestigious music room, which has four Caspian UVC’s carefully concealed in the fabric of the building. The concealment of the fan convectors has been done beautifully, without any compromise to the internal fabric of the building or to the fan convection heating. Caspian UVC fan convectors are not the only solution to heat older historic buildings. A good example of a more recognisable fan convector is at Doddington Hall on the outskirts of Lincoln. Careful consideration was needed with the provision of heating particularly in the top floor gallery which had never previously been heated. The overriding concern throughout the building was to prevent overheating, as this would have a potentially negative affect on the antique furnishings and artwork. The Caspian FF and UVC units were deployed to provide a discreet solution. To enhance this further, many of the units were produced in colours to match the historic and beautiful interiors. The Caspian FF units have been used with a reverse air flow to further reduce any impact on artefacts and exhibits. Blending valves were installed to reduce the flow temperature to 50°C, which effectively turned the Caspian FF units into Low Surface Temperature (LST) units, but the outputs can be increased by raising the flow temperature if required.


Fan convector control in inaccessible places


Doddington Hall is a good example of using controls to provide a bespoke solution for each room. Fan speed controls were provided on the units in varying positions, to allow the staff and family to control the output, whilst maintaining the required aesthetics. Every room is controlled by an RF room stat and where there is more than one heater in a room, they are linked together by a 0 – 10V signal cable. This solution again helped to reduce to a minimum any unwarranted visual impact of thermostats. There is certainly an increase in the interest in more sophisticated control systems now. Our Smart Controls are becoming more widely specified whereby remote monitoring and management of the heat emitters and heating system can be managed via an app on a mobile phone or tablet so a facilities manager, or even a heating engineer can keep an eye on things from afar. Smart Controls also offer a much more accurate control of the heat emitters.


The beauty of installing fan convectors in historical buildings is that as well as being able to blend into the fabric of the buildings they also can provide high heat outputs to quickly heat large spaces when required and then maintain heating comfort quietly in the background.


www.smithsep.co.uk 01245 324900


- Caspian UVC concealed heating fan convectors were developed for recessed or concealed heating projects making it perfect for installation in historical buildings


- A wide range of accessories is available to create the recessed or concealed heating solution required


- Suitable for high, low or ceiling concealed installations – it can even be turned upside down


- Available with Smart Controls for increased efficiency and remote monitoring and management


- Compatible with most types of wet central heating systems, functioning equally efficiently with conventional boilers, biomass technology or heat-pumps


Caspian UVC is a concealed heating solution for historical buildings


01245 324900 | sales@smithsep.co.uk SmithsEP.co.uk | @SmithsEP_UK | #ThinkSmiths Read the latest at: www.bsee.co.uk SMTHS_BSEE_128x358mm_HERITAGE.indd 1 Smiths EP hp BSEE Sep22.indd 1 BUILDING SERVICES & ENVIRONMENTAL ENGINEER SEPTEMBER 2022 7 26/07/2022 15:59 8/8/22 10:45


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50