BSEE


Cable management has constantly evolved throughout the years, from tradional methods such as onsite installaon to preassembled cable soluons. John Brodie, of HellermannTyton, discusses these changes and comments on the latest regulaon change, the 18th Edion Wiring Regulaons, and what that means for cable management


installation, although that of course helps, but the other benefits that a good cable management system can bring. Whether it’s to save time during installation, to simplify the increasingly complex electrical infrastructure in our homes and businesses, or to make buildings safer, cable management can play a vital role.


E Modular systems


Modular buildings are being seen as a solution to the demand for new build construction, and with good reason. Reports suggest that modular systems typically reduce on-site installation times by up to 70 per cent. Modular building manufacturers are therefore looking for new ways to manage their appliances and cables to reduce downtime and costs.


New methods, such as refabricated connectors and pre-assembled cables, can mean a reliable and flexible wiring solution that performs significantly better than alternative systems, in less time to install. Offering pre-assembled cable solutions reduces excessive management from electricians, therefore reducing any on site risks for the installer. Installing or working with a modular cabling system requires minimal maintenance, allowing spare time to be put to good use elsewhere.


lectrical contractors have always understood the advantages of effective cable


management. It’s not just about the virtues of a tidy


Site waste and cable snagging, two of the most common issues with traditional wiring systems due to inadequate cable management, are reduced or eliminated with modular cable systems. This brings greater safety on the site. Quality assurance is guaranteed because the modular approach uses a controlled environment to test the wiring accessories.


The electrical wiring and accessories sector is gradually evolving and taking up new technologies and methods of construction. Not only is there a new skilled workforce ready but the sector is also learning to become prefabricated, lean, and green. This is promising particularly in a period when on time and within budget are the two main expectations of projects.


Smart buildings & IoT


Smart buildings are now designed for more than merely keeping out the elements, residents expect the latest technology and comfort in this modern age. With a large diversity of smart devices, Wi-Fi and data centres cable management has never been more crucial to keep smart buildings functioning efficiently.


Whether a business is constructing a new premises, or adapting an existing location, it’s beneficial to consider at a reasonably early stage how the building’s cabled nervous system will be installed or adapted.


Safety & regulations


As cable management adapts, so do the regulations, ensuring all safety standards are met when working in a modern environment. However, keeping up with the recent regulations as they change is a vital part of workplace safety whilst changing with the times.


Cable management is important in many fields, such as IT,


communications, power distribution, facility wiring, local area networks and much more. Keeping all occupants safe whilst out on the job is imperative, working to the most recent regulations ensures all bases are covered within the workplace.


In January 2019, the 18th Edition of the IET Wiring Regulations (BS 7671)


came into force. While previous IET wiring regulations referred to ‘escape routes’, the new regulations have now expanded the scope of coverage to include ‘access or egress routes’, meaning both entry routes in and exit routes out of the building are covered. When fixing cables to exposed surfaces vertically and horizontally, the spacing of metal fixings should be approximately 250-400mm. HellermannTyton does not recommend that plastic fixings are used as the only method of fixing and should only be used in addition to sufficient metal fixing.


In addition to BS 7671, there are other standards to consider for new installations. BS 5839 gives recommendations for fire detection devices and fire alarm systems for buildings and BS 5266 gives recommendations for emergency escape lighting.


Both standards recognise the danger of collapsing cable supports in a fire, a danger which will be reduced with the introduction of the requirement of metal fixings in the 18th Edition. HellermannTyton has an in-house design team and its own manufacturing capability, so can provide expert advice on cable management as well as bespoke solutions. With this capability, HellermannTyton can create solutions to meet the needs of electrical installation contractors.


www.hellermanntyton.co.uk/competences/cable-ties-and-fixings


CABLE MANAGEMENT Cable management’s next steps


uHellermannTyton’s metal porolio includes es, mounts, tools, markers, conduits and fings that meet new regulaons for fire resistant cable support





As cable management adapts so do the regulaons, ensuring all safety standards are met when working in a modern environment





8 BUILDING SERVICES & ENVIRONMENTAL ENGINEER NOVEMBER 2019


Read the latest at: www.bsee.co.uk


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51