BSEE ENERGY MANAGEMENT
Advertising: 01622 699116 Editorial: 01354 461430
HEAT PUMP SYSTEMS Finding the perfect partner
A key concern for specifiers is how a building can be heated and cooled in the most efficient and futureproof way. Heat pumps are likely to play an increasingly vital role in the coming years, with BSRIA predicting that they will feature in over 59 million dwellings by 2020.i But to maximise these systems, the right partner products must be specified. Claire Owen, Managing Director at Jaga UK, discusses the options.
before. Whether it’s a retrofit project or a new build, there is a push from both the Government and consumers for greater sustainability – and the efficiency and environmental benefits which that translates to, in both domestic and commercial properties. Balanced with this is the need to provide efficient temperature control and comfort. In a 2016 pulse survey by the Energy Saving Trust, nearly a fifth of participants noted it was hard to keep consistently warm, with 19 per cent reporting that there were cold areas and drafts in their home.ii
E Meanwhile, a
separate study found that 1 in 5 UK employees are too cold in the workplace, meaning that thermal comfort is a serious consideration for residential and commercial specifiers alike.iii With this in mind, heat pumps are becoming an increasingly popular solution. Estimated to reduce electricity use (and cost) for heating by around 50 per cent compared to electric resistance heaters, these systems are a winner in terms of efficiency and, when utilised properly, can also provide excellent thermal comfort.iv
And,
following the recent rise in Renewable Heat Incentive (RHI) tariff payments for ground source and air source heat pumps, it seems inevitable that these technologies will enjoy a resulting increase in popularity in the domestic arena and beyond.
However, there is more to creating an energy efficient heating system than specifying a heat pump – the products it is coupled with must also be selected for maximum efficacy.
Low temperature systems uThe Knockonwood LowH2 O
radiator has a curved wooden shell finish in highgrade veneer.
Historically, low temperature systems such as ground or air source heat pumps have been partnered almost exclusively with underfloor heating, as standard steel panel radiators struggle to provide the wide surface area necessary for effective heat distribution. However, despite its popularity, underfloor heating does have significant limitations. Underfloor heating needs a wide surface area to get up to temperature, and therefore requires a
veryone involved in building development knows that ensuring optimum efficiency is now a more important consideration than ever
uJaga DBE (Dynamic Boost Effect) radiators, can quickly and efficiently heat a room.
large amount of water. For a standard low temperature10kW wet underfloor system, with a 45/35/20°C temperature profile, an average of 29 litres of water needs to be heated, which means spaces which utilise this technology can take up to four hours to reach optimum temperature. Equally, underfloor systems take hours to cool back down, meaning that for several hours of the day, the temperature is either too low or too high. As a result, underfloor heating cannot respond effectively to the demands of a building, necessitating long lead times to adjust the temperature in line with changing demand.
From an energy efficiency perspective, a system such as the above equates to around 1.97m cu of gas when used with a traditional condenser boiler for start-up consumption, and, given that electricity is generally 8 pence more than gas per kW hour, this is likely to be similarly expensive and equally inefficient.
Making the most of a heat pump system
So, what is the answer to making the most of a heat pump powered heating system? Low-H2
O radiators used in
connection with fan assisted technology are ideally suited to low temperature systems. For example, in a similar 10kW system, a Jaga Low H2
O
radiator requires just 3.2 litres of water – 90 per cent less than an underfloor system like the one mentioned above. The aluminium and copper heat exchanger rapidly transfers the heat to the room taking only two minutes to warm up and achieve the same ultimate output. With less water being used, Low- H2
O radiators can respond
faster than higher water content counterparts, consequently consuming less energy. This translates to a massively reduced level of start-up energy consumption, with gas usage in the same 10kW system amounting to just 0.05m cu.
Studies conducted by independent testing, inspection and certification body BRE (and more recently verified by Dutch body Kiwa) have shown that Jaga’s Tempo Low-H2
O radiators
consumed 5-16 per cent less energy than a system with steel panel radiators, as they are able to achieve the desired temperature more rapidly, and less heat is wasted through unnecessary over-heating.
32 BUILDING SERVICES & ENVIRONMENTAL ENGINEER NOVEMBER 2017 uStudies have proven that LowH2
By utilising fan assisted DBE (Dynamic Boost Effect) technology, air flow and heat output levels are boosted to easily meet occupants’ temperature needs quickly and efficiently. This means that there is no need to compensate for the low water temperature system by radiator oversizing, making Low-H2
O with DBE
the perfect partner for heat pumps. As a further benefit, choosing free standing or wall-mounted Low-H2
O
radiators over underfloor heating means the floor cavity can be shallower, potentially saving enough room to add a full additional floor to a multi-storey building.
However, specifiers may find they have to work around an existing underfloor set-up, either because a system is already installed, or simply because a client particularly likes underfloor heating. In cases such as these, Low-H2
provide a solution. By combining underfloor heating with Low-H2
O radiators can also O
radiators, a low baseline of heat can be provided by the underfloor system, supplemented by dynamic boosts of heat from the highly responsive radiators, meaning greater levels of thermal control are achieved more quickly and more consistently. The current emphasis on sustainability and energy efficiency is here to stay, and as a result, so are low temperature systems such as ground and air source heat pumps. Whilst underfloor heating has traditionally been seen as the go-to partner for systems such as these, the reality is that there are now much more efficient options available, which not only reduce energy consumption but also provide a far greater level of thermal comfort. For specifiers, Low-H2
O radiators are the ideal
solution, offering dynamic heating in the most efficient possible way.
www.jaga.co.uk
https://www.bsria.co.uk/download/asset/ krystyna-dawson-presentation.pdf
Sources: i
ii
http://www.energysavingtrust.org.uk/ resources/our-research-and-publications
iii
https://www.thesun.co.uk/news/2652709/ offices-cold-temperature-rights/
iv
https://energy.gov/energysaver/ heat-pump-systems
VISIT OUR WEBSITE:
www.bsee.co.uk ‘
Heat pumps are becoming an increasingly popular solution. Estimated to reduce electricity use (and cost) for heating by around 50 per cent compared to electric resistance heaters, these systems are a winner in terms of efficiency.
’ O radiators are 516% more economical than average steel panel radiators.
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56