With fire detector technology constantly evolving, standards also change in order to keep up with the latest developments. Neil Baldwin, Sales Director at leading safety and security product specialist, ESP, looks at the revised BS 58391:2017 standard, to help contractors understand the changes.


S 5839-1:2017 fire detection and fire alarm systems for buildings standard provides recommendations for the planning, design, installation, commissioning and maintenance of fire detection and fire alarm systems in and around non-domestic premises. The standard is there for anyone involved in the design and planning of fire detection and alarm systems, as well as installation and commissioning specialists.


B


The BS5839-1 revision adopts the latest industry thinking and new technologies, including added guidance on the use of call points and multi- sensor fire detectors, with the aim of reducing the incidence of false alarms.


The main change relates to manual call points. All manual call points must have some variety of protective cover. This should help prevent accidental activation from impact and also should force users of the fire alarm system to lift the cover before activation, thereby adding an extra action to the process of pressing the alarm. This should help reduce the number of times the button is pressed accidentally and make anyone who intends to push the manual call point (whether maliciously or not) to think about whether the alarm actually should be triggered.


Call point cover


Of course, covers for manual call points are now not new pieces of equipment, and many manufacturers have been producing them for some time. However, the new thing to remember is that any new installation work must use a call point cover to meet with the revised standard. Does this mean retroactively fitting call point covers on all currently existing call points? The simple answer is no, not necessarily. The standard only really applies for any new work undertaken since the publication of the standard (31st August





The BS58391 revision adopts the latest industry thinking and new technologies, including added guidance on the use of call points and mulsensor fire detectors, with the aim of reducing the incidence of false alarms.





Adversing: 01622 699116 Editorial: 01354 461430


REVISED FIRE SAFETY MEASURES A guide to the BS 58391:2017 changes


2017). However should a client request an upgrade, then of course this can be provided. Alternatively, this can be done at the next convenient time, for example, at the next service. The decision about whether to retroactively fit covers an all manual call points in a building should be down to the Responsible Person or Duty Holder.


Another change in the update is point 20.1 – the ‘place of ultimate safety’, where the clause has been expanded to place emphasis on this. The reason for the change is because not all exits of a building are specifically designed as fire exits and during the course of a fire, people will use any exit (regardless of whether it is a designated fire exit). For example, some openings in the building envelope (such as a roller shutter door) are not normally considered as a pedestrian exit, but in an emergency are likely to be used as such. Therefore manual call points should be located on escape routes and, in particular, at all storey exits and all exits to open air that lead to an ultimate place of safety (whether or not the exits are specifically designated as fire exits).


Mulsensor detectors


In addition, the standard has also been updated in regards to multi-sensor detectors. Those that have fire sensitivity of BS EN 54-7 are now acknowledged as suitable for fire escape routes but their configuration must include smoke detector mode.


The updated standard also makes clear about the method of inspection and servicing for multi- sensor detectors. Clause 45.4 states recommendations for inspection and test of the system over a 12-month period. In the first instance ‘Multi-sensor detectors should be operated by a method that confirms that products of combustion in the vicinity of the detector can reach the sensors and that a fire signal can be produced as appropriate’.


In addition, ‘the guidance of the manufacturer on the manner in which the detector can be functionally tested effectively should be followed’, and ‘multi-sensor fire detectors should be physically tested by a method that confirms that products of combustion in the vicinity of the detector can reach the sensors and that the appropriate response is confirmed at the CIE’. Where the detector or system design permits, each sensor on which a fire detection decision depends (e.g. smoke, heat, CO) should be


uAn ESP call point installaon in progress.


physically tested individually. Alternatively, individual sensors may be physically tested together if the detection system design allows simultaneous stimuli and individual sensor responses to be verified either individually or collectively. On completion of tests the system should be returned to its normal configuration.


Fire detectors


It is also worthy to note that in stairways, the update to the standard says that fire detectors should be sited at the top of the stairway and on each main landing. This is to ensure that there is adequate coverage at every level of the building as plumes of smoke are unpredictable and there is no exact way of knowing where the smoke will go, meaning that if detectors are not sited correctly, there could be a delay in the amount of time between the fire starting the system activating an alarm.


A matter of minutes – or even a few seconds – may be the difference between the fire being small and manageable and the fire being a huge emergency. The sooner a fire is detected, the sooner it can be extinguished. uBS5839:1-2017 was published on 31 August 2017 and supersedes BS 5839-1:2013 which is now withdrawn.


www.espuk.com


28 B A L E R IL T IR S V


MAY 2018 IN G N U D IC O & M


VISIT OUR WEBSITE: www.bsee.co.uk


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50