search.noResults

search.searching

saml.title
dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
Instrumentation Live Supplement B


INTRINSICALLY SAFE OPERATOR DISPLAY CAN BE MOUNTED IN AN EX E ENCLOSURE


EKA associates are proud to announce a second version of Pageant, their intrin- sically safe Operator Display. Thanks to a certified impact resistant front panel, the new display can be mounted in an Ex e or Ex t enclosure without invalidating


the certification of the enclosure. This allows the new BA3102 Display, which retains all of the original state of the art features, to be safely installed in the same cubicle or enclosure as other Zone 1 or 2 equipment. The original and new models simplify the design and reduce the cost of providing an Operator Display, Modbus Remote Display, or a PLC in a hazardous area. Multiple variables can be displayed simulta- neously, and eight touch buttons with tricolour LED annunciators accept operator inputs. Intrinsic safety Ex ia protection provides maximum safety and allows installation in almost any flammable gas or combus- tible dust atmosphere in any Zone.


Featuring a 7 inch backlit trans-reflective display which can be read in all lighting conditions, Pageant and each of its plug-in I/O modules, have separate apparatus certificates allowing installation in Zones 0, 1, 2, 20, 21 and 22. The IECEx, ATEX


and UKCA certifications permit any combination of plug-in modules to be fitted to the display without the need for additional certification. Plug-in input and output modules for interfacing 4/20mA currents, switch contacts, proximity detectors and pulse sources are available.


Pageant employs industry standard CODESYS® runtime software which complies with IEC 61131. The software includes a wealth of features and func- tion blocks and is supplied with a lifetime licence. CODESYS runtime software is an industry standard already installed in more than 1,500 different products worldwide. It is supported by extensive documentation, including video presentations, and will already be familiar to many users.


The display, eight programmable touch buttons and LED annunciators are mounted behind a 4mm thick toughened glass, or a scratch resistant polycarbonate window in the 316 stainless steel front panel. The front provides IP66 protection, is totally flat and easy to clean, making these Operator Displays ideal for petro- chemical, pharmaceutical and distilling applications. Both Operator Displays are lightweight and dissipate less than 5W limiting enclosure heating.


Pageant Operator Displays have been designed to be powered by a BEKA Power Isolator which may be mounted in a safe area or in Zone 2. Two models are available, the BA212 for applications in IIA, IIB gases and dust atmospheres and the BA243 for IIC gas applications.


Visit the BEKA associates team on stand i-31 at Instrumentation Live.


BEKA associates


www.beka.co.uk/pageant T: 01462 438301


PAGEANT ZONE 1 INTRINSICALLY SAFE OPERATOR PANEL


HMI, PLC, Modular I/O & Comms


NEW OPTION Certified impact resistant front panel


 Ex ia intrinsic safety allows installation in Zones 1, 2, 21 or 22


 Two alternative Operator Displays, both with IP66 stainless steel front panels


BA3101 Toughened glass window BA3102 Certified impact resistant front panel allows installation in Ex e and Ex t enclosures.


 7 Inch backlit operator screen  IEC 61131 compliant PLC  Up to 7 plug-in input or output modules  8 touch buttons with tricolour annunciators  3 year guarantee


www.beka.co.uk sales@beka.co.uk Hitchin SG5 2DA UK +44 (0) 1462 438301


52 January 2025 Instrumentation Monthly


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80  |  Page 81  |  Page 82  |  Page 83  |  Page 84  |  Page 85  |  Page 86  |  Page 87  |  Page 88  |  Page 89  |  Page 90  |  Page 91  |  Page 92  |  Page 93  |  Page 94  |  Page 95  |  Page 96