search.noResults

search.searching

dataCollection.invalidEmail
note.createNoteMessage

search.noResults

search.searching

orderForm.title

orderForm.productCode
orderForm.description
orderForm.quantity
orderForm.itemPrice
orderForm.price
orderForm.totalPrice
orderForm.deliveryDetails.billingAddress
orderForm.deliveryDetails.deliveryAddress
orderForm.noItems
ADVERTORIALS


ARE YOU LOOKING TO IMPROVE YOUR CONTROL PANELS?


clients with cost reductions and product improvements. One client enjoyed a staggering 90% reduction in control panel build time simply by implementing a bespoke pcb.


A Our bespoke instrumentation can help you


• Reduce build costs • Improve reliability • Reduce commissioning and maintenance costs


• Overcome obsolescence


With little or no capital outlay you could reduce the cost, size and complexity of your instrumentation.


AIID Solutions u 0161 4803163 u www.aiid.co.uk


services to ISO 17025 from the UK’s leading calibration laboratory for mass flow meters, controllers and anemometers. With some of the leading measurement uncertainties and most the diverse array of flow calibration facilities, the laboratory can undertake liquid flow calibration on water, oil, alcohol and fuels from 0.1 ml/hr to 1000 litres/min. The airflow laboratory encompasses flow calibrations from 1 cc/min to 1200 litres/sec covering meters up to 300 mm in diameter, including variable area, mass flow meters, controllers, laminar, turbine, thermal and venturi style flowmeters. Anemometer, pitot tube and air velocity type devices a can be calibrated from 0.05 m/s to 80 m/s in the UK’s best measurement accuracy wind tunnels.


FLOW CALIBRATION SERVICES U


KAS Flow & Air Velocity calibration


Young Calibration Ltd u 01273 455 572 u www.youngcalibration.co.uk


IID Solutions provide custom instrumentation, primarily to the U.K. OEM market. Specialising in control panel replacement we have a proven track record of helping


ROBUST, CHEMICALLY RESISTANT FLOWMETER O


val Gear (OG2) flowmeters from Titan Enterprises


provide an ideal solution for applications that require a highly accurate and chemically resistant flow measurement device. There is a choice of


construction materials for the OG2 flowmeter, including totally non-metallic wetted components, like ceramic, a choice of elastomer, and PEEK for metering aggressive chemicals. OG2 flowmeters are compact and have a rugged design, which allows them to operate


reliably even at higher pressure, providing steady performance with minimal maintenance. Furthermore, OG2 flowmeters are able to operate at temperatures up to 150°C and are fully IP67/NEMA 4 compliant. Each OG2 flowmeter comes with a pressure test certificate that verifies the device's ability to handle pressures up to 700 bars (for OG2-700 model). With a standard flow range from 0.03 to 4.0l/min on 30cSt oil, OG2 flowmeters are


able to regularly achieve outstanding repeatability (0.1%) and accuracy (0.75%). Titan Enterprises u 01935 812790 u wwww.flowmeters.co.uk


LEMO TO EXHIBIT ITS LATEST COMPACT FIBRE- OPTIC TERMINATION BOX AT BVE 2019


compact fibre-optic termination boxes at the UK’s largest Broadcast Video Expo 2019 on Stand No. K34 which is being held from 26th to 28th February 2019 at the London ExCel Centre. The company’s latest


L


Compact Splice Tray (CST) offers users the ability to quickly and easily install a space saving, robust HD video bulkhead interface solution without compromising performance and is now available with many new features including a quick release cover. Also on show will be LEMO’s industry leading range of broadcast interconnect and media converter solutions – offering a broad spectrum of the latest technology options to customers.


LEMO (UK) Ltd u 01903 234543 u www.lemo.com u Stand No. K34


CONTINUOUS LEVEL MEASUREMENT WITH GUIDED RADAR SENSORS


interface measurement. The guided radar pulses along the probe ensure precise and stable measurement with an absolute repeatability of ± 1mm and a maximum non-linearity of ± 2mm.


G


These rugged sensors in IP66/ IP68 stainless steel housings have a maximum cycle time of 500 ms and independent of pressure or temperature fluctuations and unaffected by foam, vapor or dust. Buildup on the probe or container walls also has no effect on the measurement. With a measuring length of up to 75 meters, these sensors enable a wide range of applications, from small filling tanks to large storage tanks - anything is possible.


Their measuring principle and mechanical design make these guided radar sensors the ideal choice for use in harsh environments. Hygiene compatible versions for pharmaceutical and food applications are available. The ATEX certified sensors can also be used in explosion hazard areas as typically found in refineries and chemical processing.


Simple key presses are all that is required for setup and teach-in. A highly visible display alerts the user to the status and ensure a correct and continuous overview. The measuring results are available on the output as an analog 4...20mA/HART signal.


Balluff u 01606 812 777 u www.balluff.co.uk


uided radar sensors from Balluff are virtually predestined for maintenance-free level measurement of liquids and solids as well as for


EMO will be showcasing their new improved


Instrumentation Monthly February 2019


67


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78  |  Page 79  |  Page 80