Sensors & transducers
ntegrated connectivity means that all relevant industrial Ethernet interfaces are integrated into the sensor. It sounds simple but is not standard on the market. Instead, manufacturers often offer devices without an industrial Ethernet interface to save development effort. In such cases, the interface is available via a gateway. The following examples show why this is not the optimal solution and why the system operator benefits in multiple ways with integrated connectivity from Leuze. The benefits range from commissioning (device management) to machine monitoring (condition monitoring) to process optimisation.
I
STREAMLINED SYSTEM LAYOUT Leuze offers devices with integrated interfaces for PROFINET, Ethernet/IP, and EtherCAT. The significant advantage that can already be gained during commissioning is demonstrated using design example with and without integrated connectivity. First a look at systems with barcode readers without integrated interfaces: here, each scanner must be connected to a separate gateway - this means an additional gateway with its own power supply for each barcode reader. As a result, the installation effort and the number of cables are twice as much as needed. The parameterisation is also considerably more complex. Do not forget: because of the required gateways, there are significantly more devices in the system that can cause a malfunction and must be checked. In comparison, in the same system with integrated connectivity, the industrial Ethernet interface is already integrated into every bar code reader. This makes separate gateways superfluous. Above all, the system layout is very clean and requires fewer cables. Last but not least, errors can be eliminated more quickly as fewer devices have to be checked.
SWITCH INCLUDED Leuze sensors with integrated connectivity also have an additional feature that contributes to efficient commissioning: the devices have one switch as standard, i.e. an Ethernet input port and output port each. As a result, system operators do not need an external switch. In addition, several devices can be wired more easily, for example in a ring or linear topology. With linear wiring, the system operator connects one sensor to another through integrated switches. Only the last sensor in the chain is connected to the controller. The advantage here is also a simpler system design and fewer cables. Devices without an integrated switch, on the other hand, require an external Ethernet switch. Users must also connect each individual sensor to the switch via a star topology and then connect this to the controller.
THE USUAL CONTROL ENVIRONMENT Integrated connectivity also means that you can work in your usual control environment. This is possible because the entire device
parametrisation is integrated into the GSDML file (”Generic Station Description Markup Language”) of PROFINET, for example. In
34 May 2023 Instrumentation Monthly
INTEGRATED CONNECTIVITY: INCREASED EFFICIENCY, IMPROVED COMMISSIONING, MACHINE MONITORING AND PROCESS OPTIMISATION
contrast, many other Ethernet-based devices on the market generally have to be parametrised via a web server. This is complicated because each manufacturer provides its own web server version with its own user interface. Users have to familiarise themselves with new interfaces every time and find the corresponding functions. In addition: devices without Ethernet that are connected via a gateway often require productspecific manufacturer's software for parametrisation. This may result in compatibility issues with the hardware used. For example, if the manufacturer does not update their software after a few years. Here too, integrated connectivity has multiple advantages: users remain in their usual control environment; no manufacturer software installation and related training required; and no need to access a web server. Leuze devices with integrated connectivity are very easy to parametrise. Only the GSDML file has to be downloaded from the Leuze website via the control and copied once into your engineering software. The modules are then available in the hardware catalogue. The function of the device is explained in a clear and concise way. This makes parametrization
and sensor usage easy and the manual is not required in most cases.
SUPPORT FROM THE SENSOR A look at the sensor’s device profile with integrated connectivity further simplifies programming. As an example: for the AMS and BPS positioning sensors, Leuze not only provides positioning values but also a calculated speed value. Anyone who needs this value in their system saves time as it does not need to be calculated. In addition, if you only want to filter for certain barcodes without integrated connectivity, you have to do this via the controller. Leuze BCL bar code readers can be done more efficiently because here you can prefilter according to specific criteria. Only codes which correspond to the required pattern
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52 |
Page 53 |
Page 54 |
Page 55 |
Page 56 |
Page 57 |
Page 58 |
Page 59 |
Page 60 |
Page 61 |
Page 62 |
Page 63 |
Page 64 |
Page 65 |
Page 66 |
Page 67 |
Page 68 |
Page 69 |
Page 70 |
Page 71 |
Page 72 |
Page 73 |
Page 74 |
Page 75 |
Page 76 |
Page 77 |
Page 78 |
Page 79 |
Page 80 |
Page 81 |
Page 82