Flow, level & control


Bürkert eDIP Platform ProvIDes value anD sImPlIcIty for network IntegratIon


Industry 4.0 ready network. Bürkert, a leading manufacturer of measurement and control systems for liquids and gases, is offering integrators the opportunity to achieve both with its innovative Efficient Device Integration Platform (EDIP). The platform takes advantage of CANopen to reduce reliance on expensive manufacturer hardware and standardise the monitoring and control of Bürkert valves, flowmeters and controllers.


F Breaking reliance on chipsets


While system integrators have a wide selection of data communication protocols to choose from when implementing an Industry 4.0 network, once a protocol is chosen, customers are usually locked in to using corresponding manufacturer’s hardware to ensure effective communication. This usually takes the form of chipsets, which will not only be required for the PLC, but for individual devices to communicate on the network too. The issue for system integrators is that


manufacturers tend to charge a premium for chipsets. For a network containing multiple devices, this can result in a high initial purchase cost. In a system incorporating 20 valves for example, a corresponding number of manufacturer chips would be required to ensure seamless communication. However, there are other ways to ensure peer


to peer communication. Open data communication protocols such as CANopen provide a solution. Manufacturer and open data communication protocols can be combined within the same network, reducing reliance on premium chipsets without comprising functionality.


eDip


Bürkert achieves this with its EDIP platform, built on the CANopen protocol, which allows intelligent networking of multiple Bürkert devices. Instead of relying on chipsets to ensure


communication with the PLC, EDIP utilises a gateway that allows information provided by devices in CANopen to be translated into whichever manufacturer protocol is desired for the PLC, and vice versa. Therefore, only one manufacturer chip installed in the gateway is required for seamless integration. EDIP provides full monitoring and control functionality, without a reliance on premium chipsets. The immediate consequence of this technology


is that it lowers the total cost of implementing an Industry 4.0 ready network. This cost saving is transmitted directly to the end user. However, with EDIP this is achieved without any


compromise in functionality. The PLC still functions in its native protocol, whether that be PROFINET, EtherNet/IP, Modbus TCP or PROFIBUS. It provides the same parameters and information, with no disadvantage in terms of writing programmes for the PLC either. Communication is seamless.


Instrumentation Monthly June 2021


or system integrators, it is often a balancing act between cost-effectiveness and functionality when implementing an


the Benefits of a stanDarDiseD interface


EDIP’s proficiencies extend well beyond savings at initial purchase. The platform standardises the interfaces between all Bürkert devices, allowing for simplified integration and operation. With Bürkert offering a wide range of valves, flowmeters and controllers that are all EDIP compatible, system integrators have great flexibility in terms of device choice too – all from a trusted source. When a network is created in EDIP, all parameters and configurations are saved in the gateway. EDIP can recognise when a valve or other device is removed from the system for maintenance, informing operators. Once a repair is complete, the device can be reinstalled into the system and it will be instantly recognised by EDIP. Furthermore, if a complete device replacement takes place, EDIP will recognise the new addition and automatically apply saved parameters and configurations to it seamlessly. This greatly expediates any device integration. EDIP allows maintenance flags or parameters to


be set up in the network, alerting end users to equipment that has passed a certain threshold. For example, a simple on/off valve could be assigned a maximum number of cycles before inspection is required, or, a valve that is neither fully on/off in operation could be assessed on distance travelled. EDIP offers the functionality to carry out diagnostics, find faults and trigger proactive preventative maintenance support or ensure a fast response to any failures.


a cost-effective stanDarD


While EDIP provides all the functionality expected of an Industry 4.0 monitoring and control network, its cost-effectiveness and standardisation of interfaces equips end users with a potent combination. Reducing reliance on manufacturer chipsets by


utilising gateways translating manufacturer protocols to CANopen and vice versa ensures increased value. This further enhances the benefits of integrating devices within a digital network by reducing equipment cost and simplifying implementation, maintenance and expansion. Furthermore, the innate features of the platform, such as maintenance flags and diagnostics, provide additional advantages, ensuring a cost-effective network of devices not just at point of purchase,


but throughout operation. www.burkert.co.uk


51


Page 1  |  Page 2  |  Page 3  |  Page 4  |  Page 5  |  Page 6  |  Page 7  |  Page 8  |  Page 9  |  Page 10  |  Page 11  |  Page 12  |  Page 13  |  Page 14  |  Page 15  |  Page 16  |  Page 17  |  Page 18  |  Page 19  |  Page 20  |  Page 21  |  Page 22  |  Page 23  |  Page 24  |  Page 25  |  Page 26  |  Page 27  |  Page 28  |  Page 29  |  Page 30  |  Page 31  |  Page 32  |  Page 33  |  Page 34  |  Page 35  |  Page 36  |  Page 37  |  Page 38  |  Page 39  |  Page 40  |  Page 41  |  Page 42  |  Page 43  |  Page 44  |  Page 45  |  Page 46  |  Page 47  |  Page 48  |  Page 49  |  Page 50  |  Page 51  |  Page 52  |  Page 53  |  Page 54  |  Page 55  |  Page 56  |  Page 57  |  Page 58  |  Page 59  |  Page 60  |  Page 61  |  Page 62  |  Page 63  |  Page 64  |  Page 65  |  Page 66  |  Page 67  |  Page 68  |  Page 69  |  Page 70  |  Page 71  |  Page 72  |  Page 73  |  Page 74  |  Page 75  |  Page 76  |  Page 77  |  Page 78