• • • LIGHTING & CONTROLS • • •
AUTOMATED LIGHTING FOR SMARTER BUILDINGS
By Shahid Khan, ECA’s technical manager
ways for installers to master smart lighting installations and help clients meet their energy efficiency goals. If there were ever a silver lining to the
D
coronavirus crisis, it is the renewed drive from all areas of industry and government to recover from the pandemic as a greener, more energy- efficient society. Add to that the recent advances in green
technology and climate change legislation such as the Net Zero Carbon 2050 target, and energy efficiency becomes a no-brainer for clients looking to build greener, cleaner and smarter assets and facilities managers looking to upgrade their buildings.
SMART LIGHTING - GIMMICK OR SAVIOUR?
Lighting in buildings is a major source of global carbon emissions, estimated at 20 to 40 per cent of a building’s total operational energy consumption, not to mention the embodied carbon costs associ- ated with the manufacturing of lighting products. Efficiency is a broad term on its own, but in the
context for lighting, it boils down to keeping the energy expenditure of a building at the lowest possible level without sacrificing user comfort and operational requirements. There is an almost overwhelming number of
possible approaches to smart lighting installations for both wired and wireless networks – DMX 512, KNX, Zigbee, Bluetooth, to name a few. But for simple yet functional automated lighting
controls, DALI takes the prize. DALI – Digital Addressable Lighting Interface –
is an interface protocol for digital communication between electronic lighting equipment (electronic ballasts, etc.). It is not a product but an open-source protocol: a common set of rules and commands that each device in a network must follow. DALI is supported by most global lighting control
system and component manufacturers. Therefore a network can be installed using simple 5-core LV
emand for smarter buildings is expected to skyrocket as businesses get back to work in coming months. Here, we look at the best
cabling with no segregation required, and a relatively straightforward commissioning regime making it one of the most cost-effective solutions out there. Each component of an open source DALI
network is assigned an ‘address’ which a central computer uses to communicate its pre- programmed instructions. For example, a set of lights can be programmed
to come on once the first person enters the office in the morning, switch off when no-one is present in a room or on a floor, brighten or dim throughout the day or cause the actuation of solar blinds in response to the amount of natural light coming from outside. The possibilities are (almost) limitless, so long as
the maximum number of nodes (unique addresses) is limited to 64 in a single network and are based on the programming sequence of sensors and actuators which respond to the set points input into the system at the commissioning stage. The added comfort, energy savings and cost
savings provided by DALI systems helps them pay for themselves relatively quickly, particularly in larger offices and communal dwellings like university halls of residence, hospitals or care homes.
SMARTER FACILITIES MANAGERS
Smart lighting systems can make life easier for fa- cilities managers. Emergency lighting can be tested without human interaction, so long as the lights have been programmed correctly. Parame- ters can be set up to automatically test the fittings monthly, six-monthly and annually, as per the re- quirements of BS EN 5266, and generate elec- tronic reports. These reports can then be held locally on servers, emailed to specific individuals or held in a cloud-based system to provide a ro- bust record of maintenance. As each ballast has a unique address, fault-
finding also becomes an easier process. Fault reports can be automatically generated and narrowed down to easily identify a faulty component. A data-informed decision can then be made to dispatch an engineer to fix the problem – saving time and money in the process.
34 ELECTRICAL ENGINEERING • SEPTEMBER 2020 NEW CHALLENGES
As with any new system, there are risks and challenges that contractors and installers should recognise. Automatic lighting controls can present a steep
learning curve for FMs new to smart systems. DALI is a great first step, owing to its simplicity and ease of installation. Initial programming can also be laborious when first installing a system. As with any open source protocol, there is an
added risk of cyber-attacks. However, this can be mitigated by using closed networks and having robust security measures in place. Engineers should have a strong knowledge of basic programming and security systems before making smart lighting installations a part of their arsenal. Connecting to HVAC DALI is specific only to lighting controls, however
for combined control of lighting and HVAC (which uses a different open source protocol called BACnet), different protocols can be made to work in concert using a ‘gateway’. A gateway will translate one protocol, in this case
DALI, into one that BACnet can utilise and which can be controlled using one building management system, via one user interface. The compromise here is that the speed of data
transmission is slowed – though it is still largely adequate for building services applications. Although somewhat removed from the world of
the electrician, it will become increasingly important for contractors and installers to be aware of HVAC automation systems as demand for these, and for total building automation and control systems, is likely to rise.
LIGHTING THE WAY
In short, automatic digital lighting controls have been around for a while and are most definitely here to stay. They make for better-performing, energy efficient
buildings and can be tailored to an almost limitless range of user needs. Installers should see this as an opportunity to grow and offer much-needed expertise to FM teams across the country. ECA |
eca.co.uk
electricalengineeringmagazine.co.uk
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50 |
Page 51 |
Page 52