nVent to offer a scalable solution for high-density racks
Revolutionary new RDHX PRO rear door coolers (RDC) from nVent meets the need for vastly increased data processing power requirements of AI-enhanced software applications
Vent, a leading global provider of electrical connection and protection solutions, has announced the launch of its RDHX PRO rear door cooling unit, a revolutionary new high-performance solution offering the capability to upgrade data centres with up to 83kW high-density racks, meeting the requirements for the growing use of AI-enhanced applications, demands for higher energy efficiency and sustainability, and the need for greater data centre space utilisation. Rear door cooling solutions are increasingly popular as a pay-as-you-go method for retrofitting increased data centre cooling performance, in many cases without the need for additional re-engineering of the existing facility mechanical design.
n
When installed as a primary method of heat removal, rear door coolers eliminate much of the need for mechanical equipment including fans, blowers and CRAHs, to provide a more optimised cooling solution aligned with the exact requirements for individual racks, at the same time reducing noise and energy waste. Marc Caiola, nVent’s vice president of data cooling and networking, said: ““The RDHX PRO RDC is an innovative rear door cooling solution which responds to trends currently converging to make life more complex for those managing data centres,” said “Our new RDC combines the ability to upgrade cooling capacity without significant
capital investment and re-equipping of existing data centre space; the opportunity to reduce the amount of power used for cooling IT as well the expense and associated emissions; and the advantage of an easily maintainable cooling solution designed and built for high availability.”
Bringing flexibility to rack cooling
One of the most impressive features of RDHX PRO RDC is the ability to operate comfortably with 57degF (14degC) warm water cooling, making it environmentally friendly. By utilising free cooling, the device significantly reduces the amount of energy required to cool the data centre, not only reducing overall data centre power consumption but also the carbon footprint of operations. The future-proofed solution can also be combined with direct-to-chip (D-2-C) liquid cooling deployments, for customers who are moving towards a hybrid approach to cooling, and especially those looking to maximise heat reuse opportunities, combined with NVent’s liquid cooling CDU 800.
RDHX PRO Rear Door Cooling for maximum compatibility and availability
The new rear door cooling units from nVent are offered in a range of standard sizes for use with
42U, 47U, 48U and 52U data centre racks, in both 600mm and 800mm widths.
The coolers themselves are 250mm deep, one of the features of rear door coolers is that they are compact and do not require any additional floor space or ceiling headroom, it can free up white space compared to other competitor RDCs and cooling devices CRAH & CRAC units may be eliminated from the data centre.
Each unit has a maximum power draw of 1800w and features 12x axial brushless DC fans – more than any competitive unit. However, the large number of fans means they individually do less work than a smaller number of large fans, reducing stress on the electromechanical devices and increasing their lifecycle. In the event failures do occur, nVent has developed an innovative, tool-less and hot- swappable method for fan replacement as well as other critical components such as PSUs. This feature allows uptime to be maximized at the same time as reducing service callouts and associated costs. For ease of integration with data centre management applications as well as BMS software, the new rear door cooling units also feature a newly designed controller which is compatible with most popular network and control protocols including Web Interface, Ethernet, SNMP, Modbus TCP, RTU, and Redfish.
20 ELECTRICAL ENGINEERING • OCTOBER 2023
electricalengineeringmagazine.co.uk
Page 1 |
Page 2 |
Page 3 |
Page 4 |
Page 5 |
Page 6 |
Page 7 |
Page 8 |
Page 9 |
Page 10 |
Page 11 |
Page 12 |
Page 13 |
Page 14 |
Page 15 |
Page 16 |
Page 17 |
Page 18 |
Page 19 |
Page 20 |
Page 21 |
Page 22 |
Page 23 |
Page 24 |
Page 25 |
Page 26 |
Page 27 |
Page 28 |
Page 29 |
Page 30 |
Page 31 |
Page 32 |
Page 33 |
Page 34 |
Page 35 |
Page 36 |
Page 37 |
Page 38 |
Page 39 |
Page 40 |
Page 41 |
Page 42 |
Page 43 |
Page 44 |
Page 45 |
Page 46 |
Page 47 |
Page 48 |
Page 49 |
Page 50